Structure optimization for pulverized coal mixer of a 300 MW unit boiler
|更新时间:2025-09-28
|
Structure optimization for pulverized coal mixer of a 300 MW unit boiler
Thermal Power GenerationVol. 46, Issue 6, Pages: 141-144(2017)
作者机构:
1. 淮浙煤电有限责任公司凤台发电分公司
2. 西安热工研究院有限公司
3. 华能聊热发电有限公司
作者简介:
基金信息:
DOI:
CLC:TM621.2
Published:2017
稿件说明:
移动端阅览
ZHU Zhaoyang, ZHOU Fei, MU Weifu, et al. Structure optimization for pulverized coal mixer of a 300 MW unit boiler[J]. Thermal power generation, 2017, 46(6): 141-144.
DOI:
ZHU Zhaoyang, ZHOU Fei, MU Weifu, et al. Structure optimization for pulverized coal mixer of a 300 MW unit boiler[J]. Thermal power generation, 2017, 46(6): 141-144.DOI:
Structure optimization for pulverized coal mixer of a 300 MW unit boiler
The pulverized coal mixer is one of the important equipments in the middle storage type boiler. Its normal operation is the key to ensure the stable combustion of the pulverized coal boiler. Combing with the positive pressure off powder occurred in pulverized coal mixer of a 300 MW unit boiler under full load conditions
this paper carried out numerical simulation to analyse the flow field and particle trajectories by using the Fluent software. The large on-way resistance and local resistance of the primary air pipe behind the coal mixer and the defects in structural design of the pulverized coal mixer are considered as the major reasons for off powder. To solve this problem
it suggests that the coal mixer tray should be moved vertically down by 60 mm
and the inner side of the powder inlet be longitudinally extended by 30 mm. Moreover
numerical simulation and experiments were performed to verify the optimized structure. The results show that
after structure optimization
under full load condition
the pulverized coal output of coal mixer for a single primary air pipe increased by 3 t/h
and the coal flow at the outlet was uniform and smooth