Prediction of SO2 emission from dual-alkali desulfurization tower based on RBF neural network
|更新时间:2025-09-28
|
Prediction of SO2 emission from dual-alkali desulfurization tower based on RBF neural network
Thermal Power GenerationVol. 46, Issue 10, Pages: 58-63(2017)
作者机构:
1. 东华大学环境科学与工程学院
2. 河南潜合自动化科技有限公司
作者简介:
基金信息:
DOI:
CLC:X773;TM621
Published:2017
稿件说明:
移动端阅览
SU Xiangpeng, DIAO Yongfa, YANG Qingjie. Prediction of SO2 emission from dual-alkali desulfurization tower based on RBF neural network[J]. Thermal power generation, 2017, 46(10): 58-63.
DOI:
SU Xiangpeng, DIAO Yongfa, YANG Qingjie. Prediction of SO2 emission from dual-alkali desulfurization tower based on RBF neural network[J]. Thermal power generation, 2017, 46(10): 58-63.DOI:
Prediction of SO2 emission from dual-alkali desulfurization tower based on RBF neural network
The conventional formula estimating method for prediction of SO_2 emission from the desulfurization tower outlet is difficult to be popularized
and it is time-consuming and money-consuming by on-site measurement method. To solve this problem
a prediction method for SO_2 emission from desulfurization tower outlet based on RBF neural network was proposed in this paper. To predict the on-line monitoring data of the dual-alkali desulfurization tower. The results show that
the maximum and average deviation of the RBF neural network are both 0
indicating it is superior to the gradient varying BP neural network and the LM-BP neural network. On this basis
the RBF neural network was used as the prediction model. The input parameters are: the average flue gas temperature is 101 ℃
the average pH value of the desulfurization tower liquid is 8.40
the average liquid-gas ratio is 1.130 0 L/m3. Through continuously changing one of the input parameters
the effects of other input parameters on conversion value of SO_2 mass concentration at the desulfurization tower outlet were investigated. The results show that
the conversion value of SO_2 mass concentration increases with the flue gas temperature
it begins to fluctuate when the flue gas temperature increases to higher than 110 ℃. The conversion value of SO_2 mass concentration decreases with the increasing liquid-gas ratio. When the flue gas temperature is 101 ℃ and the liquid-gas ratio is 1.130 0 L/m3
the optimum pH value of the desulfurization tower liquid is 8.60. Therefore
the above SO_2 emission prediction method for desulfurization tower based on RBF neural network can not only effectively predict the SO_2 emission from the double alkali desulfurization tower outlet
but also can optimize the SO_2 emission reduction.