Effect of wall thickness on film cooling effectiveness: numerical simulation
|更新时间:2025-09-28
|
Effect of wall thickness on film cooling effectiveness: numerical simulation
Thermal Power GenerationVol. 46, Issue 9, Pages: 59-64(2017)
作者机构:
沈阳航空航天大学辽宁省航空推进系统先进测试技术重点实验室
作者简介:
基金信息:
DOI:
CLC:TK471
Published:2017
稿件说明:
移动端阅览
LI Guangchao, PENG Ningjian, ZHANG Wei, et al. Effect of wall thickness on film cooling effectiveness: numerical simulation[J]. Thermal power generation, 2017, 46(9): 59-64.
DOI:
LI Guangchao, PENG Ningjian, ZHANG Wei, et al. Effect of wall thickness on film cooling effectiveness: numerical simulation[J]. Thermal power generation, 2017, 46(9): 59-64.DOI:
Effect of wall thickness on film cooling effectiveness: numerical simulation
To explore the influence of thin wall size on film cooling performance
numerical simulation was carried out to investigate the flow field
temperature field and cooling effectiveness under conditions with wall thickness of one time
two times and three times of diameter of the film-cooling hole.The results show that
high-speed region appears at the hole exit with the wall thickness of one time of the hole diameter
resulting in an increase in the jet momentum and promoting the coolant being lifted off the wall.The lateral velocity of the coolant is towards to the center line of the hole
which weakens the spanwise diffusion.Compared with the wall thickness of three times of the hole diameter
the values of spanwise averaged film cooling effectiveness for one times of the hole diameter are about 9%~45%
21%~43% and 9%~62% lower at blowing ratios of 1.0
1.5 and 2.0
respectively.There is little difference in spanwise averaged film cooling effectiveness between the wall thickness of two times and three times of the hole diameter.