Energy conservation analysis for waste heat utilization system applying air preheater and using primary air to heat condensate water
|更新时间:2025-09-28
|
Energy conservation analysis for waste heat utilization system applying air preheater and using primary air to heat condensate water
Thermal Power GenerationVol. 46, Issue 10, Pages: 10-15(2017)
作者机构:
华北电力大学能源动力与机械工程学院
作者简介:
基金信息:
DOI:
CLC:TK115;TM621
Published:2017
稿件说明:
移动端阅览
WANG Jianhang, YAN Weiping, HE Dong. Energy conservation analysis for waste heat utilization system applying air preheater and using primary air to heat condensate water[J]. Thermal power generation, 2017, 46(10): 10-15.
DOI:
WANG Jianhang, YAN Weiping, HE Dong. Energy conservation analysis for waste heat utilization system applying air preheater and using primary air to heat condensate water[J]. Thermal power generation, 2017, 46(10): 10-15.DOI:
Energy conservation analysis for waste heat utilization system applying air preheater and using primary air to heat condensate water
A flue gas waste heat utilization system was proposed
which is based on capacity increase of air preheater and heating condensation water by primary air. It can control the temperature of primary air entering the pulverizing system and avoid direct mixing of the cold air for coals with low moisture content. It also can reduce the abrasion and low-temperature corrosion of the heating surface. For a supercritical 600 MW coal-fired unit
applying this system reduced the flue gas temperature by 15 ℃. Comparison of system structure
energy saving effect and economy were performed between the above waste heat utilization system and the conventional waste heat utilization system equipped with low pressure economizer. The results show that
the heat transfer area that the primary air-condensation water heat exchanger required is less than 1/3 of the low pressure economizer
and the land area the new system covers is about 1/6 of that of the conventional system. The waste heat utilization system based on capacity increase of air preheater and heating condensation water by primary air can reduce the standard coal consumption for power supply by 2.42 g/(k W·h)
which is 2.75 times as much as that of the conventional waste heat utilization system
and it can increase the average annual net income by 5.901 million yuan
which is about 3.5 times as much as that of the conventional waste heat utilization system. Therefore
the proposed flue gas waste heat utilization system saves the materials and site area
which has dramatic energy conservation and economic effect.