Optimization design of SNCR process for W-flame boiler
|更新时间:2025-09-28
|
Optimization design of SNCR process for W-flame boiler
Thermal Power GenerationVol. 46, Issue 9, Pages: 99-103(2017)
作者机构:
西安热工研究院有限公司
作者简介:
基金信息:
DOI:
CLC:X773
Published:2017
稿件说明:
移动端阅览
ZHANG Bo, XU Hongjie, ZHANG Xiangyu, et al. Optimization design of SNCR process for W-flame boiler[J]. Thermal power generation, 2017, 46(9): 99-103.
DOI:
ZHANG Bo, XU Hongjie, ZHANG Xiangyu, et al. Optimization design of SNCR process for W-flame boiler[J]. Thermal power generation, 2017, 46(9): 99-103.DOI:
Optimization design of SNCR process for W-flame boiler
To optimize the design of selective non-catalytic reduction (SNCR) process for a 600 MW W-flame boiler
the chemical kinetics analysis and fluid dynamics analysis were applied to simulate the SNCR process.The design parameters of the SNCR process including the design temperature
de-nitrification efficiency in theory and position of spray gun were determined
and a denitrification rate of 46% was finally obtained.The results show that
the chemical kinetics analysis deosn't consider the effect of nonuniform mixing of the reducing agent and NO_x
so the theoretical efficiency is higher.The fluid dynamics analysis takes into account the effect of mass transfer
so the denitrification efficiency is lower than the theoretical value.In practical engineering
the mixed mass transfer is an important factor affecting the efficiency of SNCR denitration