Experimental study on deactivation and regeneration performance of denitration catalysts
|更新时间:2025-09-28
|
Experimental study on deactivation and regeneration performance of denitration catalysts
Thermal Power GenerationVol. 46, Issue 11, Pages: 67-72(2017)
作者机构:
西安热工研究院有限公司苏州分公司
作者简介:
基金信息:
DOI:
CLC:X773
Published:2017
稿件说明:
移动端阅览
WANG Lipeng, CHEN Baokang, YAO Yan, et al. Experimental study on deactivation and regeneration performance of denitration catalysts[J]. Thermal power generation, 2017, 46(11): 67-72.
DOI:
WANG Lipeng, CHEN Baokang, YAO Yan, et al. Experimental study on deactivation and regeneration performance of denitration catalysts[J]. Thermal power generation, 2017, 46(11): 67-72.DOI:
Experimental study on deactivation and regeneration performance of denitration catalysts
Taking the deactivated and regenerated denitration catalysts used in a power plant as the research objects
the full-size catalyst performance test bench and several instruments such as XRF
BET
SEM and XRD were employed to carry out performance test and characterization analysis for the catalysts. The results show that
after 24 000 hours' operation
two layers of the catalysts could not satisfy the design requirements that the de-NOxefficiency should be higher than 83% and the ammonia escape rate be below 3 μL/L. The relative activity value of the deactivated catalyst was 0.70. After regeneration
the catalyst pores were cleared and the performance indexes of the regenerated catalyst returned to a level of new catalyst. The de-NOx efficiency and ammonia escape rate of the two layers of catalysts met the performance requirements. The SO2/SO3 conversion rate was well controlled. The relative activity value of the regenerated catalyst increased to 0.99 and the denitration performance was significantly improved.