Convective heat transfer characteristics of boiler high temperature superheater under pressurized oxygen enrichment condition
|更新时间:2025-09-28
|
Convective heat transfer characteristics of boiler high temperature superheater under pressurized oxygen enrichment condition
Thermal Power GenerationVol. 46, Issue 10, Pages: 76-80(2017)
作者机构:
1. 山西大同大学建筑与测绘工程学院
2. 国电电力大同发电有限责任公司
作者简介:
基金信息:
DOI:
CLC:TM621.3
Published:2017
稿件说明:
移动端阅览
LI Xiaomin, WANG Lijun. Convective heat transfer characteristics of boiler high temperature superheater under pressurized oxygen enrichment condition[J]. Thermal power generation, 2017, 46(10): 76-80.
DOI:
LI Xiaomin, WANG Lijun. Convective heat transfer characteristics of boiler high temperature superheater under pressurized oxygen enrichment condition[J]. Thermal power generation, 2017, 46(10): 76-80.DOI:
Convective heat transfer characteristics of boiler high temperature superheater under pressurized oxygen enrichment condition
摘要
以300 MW燃煤发电机组为研究对象
在不同烟气流速条件下
建立高温过热器优化模型。以单位时间内相同换热效果下高温换热器投资总费用最低为目标
得到增压富氧燃烧气氛下高温过热器的最佳设计结构和理想烟气流速。通过设置4种不同扰动工况下的边界条件
研究高温过热器蒸汽出口温度和动态响应时间的变化规律。结果表明:与空气气氛相比
增压富氧气氛下高温过热器蒸汽入口流量、烟气入口流量、蒸汽入口温度、烟气入口温度分别增加10%时
汽温响应时间分别缩短11.88、7.92、10.89、6.93 s
蒸汽出口温度变化量分别减少0.40、0.33、0.20、5.34 K。
Abstract
Taking a 300 MW unit coal-fired unit as the research object
a high temperature superheater surface optimization model is established under conditions with different flue gas velocities. Taking the minimum total investment cost of high temperature heat exchanger in unit time with the same heat exchange amount as the target
the optimum design structure and the most ideal flow rate of the flue gas for the high temperature superheater running in pressurized oxyfuel combustion atmosphere are determined. By setting four different boundary conditions
the change of the steam outlet temperature and the corresponding dynamic response time of the high temperature superheater are analyzed. The results show that
compared with the air atmosphere
when the steam inlet flow
gas inlet flow
steam inlet temperature and gas inlet temperature step increases by 10%
the response time of the steam temperautre in the pressurized oxygen enriched atmosphere is shortened by 11.88 s
7.92 s
10.89 s and 6.93 s
respectively
and the variation of the steam outlet temperature drop is reduced by 0.40 K