Factors influencing laying up corrosion of low temperature reheater tubes in Russian-made units
|更新时间:2025-09-28
|
Factors influencing laying up corrosion of low temperature reheater tubes in Russian-made units
Thermal Power GenerationVol. 46, Issue 11, Pages: 85-90(2017)
作者机构:
1. 神华国华(北京)电力研究院有限公司
2. 西安热工研究院有限公司
3. 神华国华绥中发电有限责任公司
4. 神华国华盘山发电有限责任公司
作者简介:
基金信息:
DOI:
CLC:TM621
Published:2017
稿件说明:
移动端阅览
ZHANG Guangwen, LIU Feng, LI Jia, et al. Factors influencing laying up corrosion of low temperature reheater tubes in Russian-made units[J]. Thermal power generation, 2017, 46(11): 85-90.
DOI:
ZHANG Guangwen, LIU Feng, LI Jia, et al. Factors influencing laying up corrosion of low temperature reheater tubes in Russian-made units[J]. Thermal power generation, 2017, 46(11): 85-90.DOI:
Factors influencing laying up corrosion of low temperature reheater tubes in Russian-made units
摘要
俄供机组低温再热器管内壁腐蚀与停机保养阶段环境因素的控制密切相关。通过模拟实验
研究相对湿度、温度等环境因素以及停机加药措施对存在积盐的低温再热器(12Cr Mo V材质)腐蚀的影响。结果表明:湿度对低温再热器腐蚀的影响最大
The corrosion of low temperature reheater tubes in Russian-made unitts has close relationship with the control of environmental factors during the unit's shutdown maintenance phase. Through simulated tests
the influences of environmental factors
such as the relative humidity and temperature
and chemical dosing process on the corrosion of low temperature reheater material(12 Cr Mo V) with salts deposition were analyzed. The results indicate that
the relative humidity affected the most
keeping the relative humidity lower than 40% can prevent the corrosion on the low temperature reheater material with salts deposition. It suggests the active amine be used to protect the low temperature reheater material. Shutdown maintenances for Russian-made unitts are proposed with consideration of the shutdown time.