Economic research on desulfurization and denitration for a supercritical 350 MW circulating fluidized bed boiler
|更新时间:2025-09-28
|
Economic research on desulfurization and denitration for a supercritical 350 MW circulating fluidized bed boiler
Thermal Power GenerationVol. 46, Issue 11, Pages: 114-118(2017)
作者机构:
神华国能(神东电力)集团
作者简介:
基金信息:
DOI:
CLC:X773
Published:2017
稿件说明:
移动端阅览
ZHANG Jiansheng. Economic research on desulfurization and denitration for a supercritical 350 MW circulating fluidized bed boiler[J]. Thermal power generation, 2017, 46(11): 114-118.
DOI:
ZHANG Jiansheng. Economic research on desulfurization and denitration for a supercritical 350 MW circulating fluidized bed boiler[J]. Thermal power generation, 2017, 46(11): 114-118.DOI:
Economic research on desulfurization and denitration for a supercritical 350 MW circulating fluidized bed boiler
For the supercritical 350 MW unit circulating fluidized bed(CFB) boiler in Shenhua Shendong Shanxi Hequ Power Generation plant(Hequ CFB plant)
the ultra low emission technological route is efficient desulfurization and nitrogen suppression in the furnace
selective non-catalytic reduction(SNCR) denitration and CFB flue gas desulfurization system outside the furnace. By means of site test
the influence of parameters such as bed temperature
oxygen concentration and mole ratio of calcium to sulfur inside the furnace on emission characteristics of NOx and SO2 was verified
and the effects of adding limestone into the furnace and setting pre-electrostatic dust precipitator on economy of desulfurization and denitration were also discussed. The results indicate that
the SO_2 concentration at entrance of the CFB flue gas desulfurization system outside the furnace can be controlled by adjusting the operation parameters. The optimal operation parameters were chosen after carefully comparing the boiler efficiency
limestone consumption inside and outside the furnace and urea consumption in the denitration system
then the optimum combustion efficiency and economy of desulfurization and denitration were achieved. Setting the pre-electrostatic dust precipitator at inlet of the CFB flue gas desulfurization system increased the unit economy. The research can provide references for the newly built and retrofitted large-scale CFB units with CFB flue gas desulfurization system.