Research on Contamination Deposition Characteristics of Post Insulator Based on Computational Fluid Dynamics
|更新时间:2025-12-08
|
Research on Contamination Deposition Characteristics of Post Insulator Based on Computational Fluid Dynamics
Vol. 41, Issue 8, Pages: 2741-2749(2015)
作者机构:
1. 清华大学深圳研究生院
2. 南方电网科学研究院
作者简介:
基金信息:
DOI:
CLC:
Published Online:31 August 2015,
Published:2015
稿件说明:
移动端阅览
WANG Liming, LIU Ting, MEI Hongwei, et al. Research on Contamination Deposition Characteristics of Post Insulator Based on Computational Fluid Dynamics[J]. 2015, 41(8): 2741-2749.
DOI:
WANG Liming, LIU Ting, MEI Hongwei, et al. Research on Contamination Deposition Characteristics of Post Insulator Based on Computational Fluid Dynamics[J]. 2015, 41(8): 2741-2749.DOI:
Research on Contamination Deposition Characteristics of Post Insulator Based on Computational Fluid Dynamics
In order to study the factors influencing insulators’ contamination deposition
we gathered the dimensions of some post insulators and set up numerical models for wind tunnel simulation. On the basis of the theory of computational fluid dynamics
we discussed four factors that affect the trapped mass of insulators. It is concluded that the concentration of particles has a linear function on the taped mass of the insulator surface. Higher wind velocity will lead to more trapped mass on both the top surfaces and the bottom surfaces of insulators
though different profiles of the top and bottom surfaces can result in distinct tends. Meanwhile
growth in the mean diameter of particles will increase the trapped mass of the top surfaces but barely affects the bottom surface. Moreover
for any certain shape of insulator
increasing the diameter of insulator rod significantly will reduce the density of contamination deposition. Further comparison indicates a considerable difference between the simulation results and some reported experimental data from wind tunnel tests
which is probably due to the insufficient consideration of the adhesion effect in the simulations.
Flashover Characteristics of Snow-covered Post Insulators in Substations
Artificial Snow-covered Withstand Voltage Test of 110 kV Polluted Post Insulator
Numerical Analysis of Contamination Characteristics of New Type Insulator for Catenary Cantilever
Analysis on Natural Contamination Characteristics for Different Types of 110 kV Post Insulators
Negative DC Flashover Performance of Post Insulators with Non-uniform Pollution on Top and Bottom Surfaces
Related Author
LIU Zehui
LU Ming
ZHANG Chuyan
LI Jianchao
ZHANG Ruobing
ZHONG Rui
LI Yangyang
LI Qing
Related Institution
Electric Power Research Institute of State Grid Henan Electric Power Company
State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University
State Grid Key Laboratory of Power Transmission Line Galloping Prevention and Control Technology, Electric Power Research Institute,State Grid henan Electric Power Company
School of Automation & Electrical Engineering, Lanzhou Jiaotong University
Department of Mechanical & Electrical Engineering,Lanzhou Institute of Technology