Design of DBD High-frequency High-voltage Power Supply and Its Discharging Characteristics
|更新时间:2025-12-08
|
Design of DBD High-frequency High-voltage Power Supply and Its Discharging Characteristics
Vol. 42, Issue 3, Pages: 807-812(2016)
作者机构:
北京航空航天大学机械工程及自动化学院
作者简介:
基金信息:
DOI:
CLC:
Published Online:31 March 2016,
Published:2016
稿件说明:
移动端阅览
QI Zewu, ZHANG Wei, LI Pinglin, et al. Design of DBD High-frequency High-voltage Power Supply and Its Discharging Characteristics[J]. 2016, 42(3): 807-812.
DOI:
QI Zewu, ZHANG Wei, LI Pinglin, et al. Design of DBD High-frequency High-voltage Power Supply and Its Discharging Characteristics[J]. 2016, 42(3): 807-812.DOI:
Design of DBD High-frequency High-voltage Power Supply and Its Discharging Characteristics
the thickness of the dielectric layers and the size of the air gap
on the characteristics of dielectric barrier discharge
using DC power supply in series with a square wave inverter as the main circuit topology
we designed a DBD high-frequency high-voltage power supply
in which the output power and frequency of the power supply could be regulated separately. DBD discharge experiments were conducted by using single-deck and double-deck Teflon as the plasma generator. Moreover
the influences of key parameters
such as compensating inductance
dielectric layer thickness
and gap size
on the resonant frequency of discharge load circuit and discharging effect were analyzed emphatically. The results show that the resonant frequency of discharge load circuit can be regulated by changing the compensating inductance
and with the dielectric layer thickness and gap size increasing
the capacitance of the dielectric capacitor and gas capacitor decreases
the resonant frequency of discharge load circuit increases
Analyses of Harmonic Transmission Characteristics of Half-wavelength AC Transmission Line Based on Pole Distribution Feature of Frequency-length Factor
Breakdown Characteristics of Heat-resistant Inter-turn Insulation Materials in High-frequency Transformers
Time-frequency Analysis Method for HF Partial Discharge Signal From Power Transformer Bushing Tap With Signal Propagation Characteristics
Analysis Method of Busbar Impedance Network Resonance Characteristics
Improved Modulation Strategy for Three-level ANPC Topology With High Stray Inductance
Related Author
YU Yongjun
YANG Honggeng
TAN Meng
CHEN Chang
ZHOU Shengjun
YANG Fuyao
LIU Yang
WAN Liujie
Related Institution
State Key Laboratory of Advanced Power Transmission Technology,Global Energy Interconnection Research Institute
School of Electrical Engineering and Information, Sichuan University
State Grid Xinjiang Electric Power Research Institute
Institute of Electrical Engineering of the Chinese Academy of Sciences