Method for Calculating Power Flow of Hybrid AC/DC Power Distribution System with Converter Station Operation Mode
|更新时间:2025-12-08
|
Method for Calculating Power Flow of Hybrid AC/DC Power Distribution System with Converter Station Operation Mode
Vol. 42, Issue 7, Pages: 2149-2157(2016)
作者机构:
1. 中国科学院电工研究所
2. 中国电力科学研究院
3. 国网北京市电力公司
作者简介:
基金信息:
DOI:
CLC:
Published Online:31 July 2016,
Published:2016
稿件说明:
移动端阅览
YANG Yanhong, PEI Wei, DENG Wei, et al. Method for Calculating Power Flow of Hybrid AC/DC Power Distribution System with Converter Station Operation Mode[J]. 2016, 42(7): 2149-2157.
DOI:
YANG Yanhong, PEI Wei, DENG Wei, et al. Method for Calculating Power Flow of Hybrid AC/DC Power Distribution System with Converter Station Operation Mode[J]. 2016, 42(7): 2149-2157.DOI:
Method for Calculating Power Flow of Hybrid AC/DC Power Distribution System with Converter Station Operation Mode
In accordance with multi-terminal direct current(VSC-MTDC) structure hybrid AC/DC power distribution system
considering AC side three-phase unbalance model and VSC converter operation control mode simultaneously
we proposed a sequential AC/DC power flow method for the voltage source converter. Meanwhile
we discussed the node equivalent processing method with VSC station master-slave and droop control mode. VSC station was treated as dummy generator in AC power flow
and three-phase unbalance method was used. Simulation results on IEEE 13 node test system show that the proposed method can flexibly handle master-slave and droop control mode of hybrid AC/DC power distribution system and fast convergence
moreover
VSC-MTDC can effectively reduce the influence of voltage distribution and three-phase unbalance caused by distribution generator. The three-phase unbalance compensation and operation optimization of hybrid AC/DC power distribution system may be further researched based on the results in this paper.