Influence of Offline Time on the Characteristic of Arc Between Pantograph and Catenary
摘要
由于高速铁路弓网离线存在随机性
离线可能发生在交流电压的任意时刻
所以需要研究离线时刻对弓网电弧特性的影响
以系统地研究弓网电弧机理。为此
基于在实验室中搭建的弓网离线模拟实验平台
进行了大量的随机离线放电实验
采集了不同离线时刻的电弧电压、电弧电流、相对光强波形及数据
并进行了统计分析。结果表明:静态弓网离线时的电弧燃弧时间在15
2
5 ms之间;在电压幅值上升区间(1
5
ms
11
1
5 ms)离线时的电弧相对光强较大
同时电弧电压的谐波含量较大;动态弓网离线时的电弧燃弧时间在1
8
ms之间;在电压幅值上升区间离线时的电弧燃弧时间要大于在电压幅值下降区间离线时的电弧燃弧时间
同时电弧电压的谐波含量较小。总之
离线时刻对静态及动态离线电弧的电气特性、燃弧时间、相对光强、谐波含量等均有不同程度的影响。
Abstract
Offline can occur in any time of the AC voltage due to the pantograph-catenary offline randomness of the high-speed railway
influence of offline time on the characteristic of pantograph-catenary offline arc should be researched so that the mechanism of the offline arc can be studied systematically. Consequently
based on the pantograph-catenary offline simulation experiment platform that is set up in the lab
a large number of random offline discharge experiments are conducted. The waveforms and data of the voltage
current
and relative light intensity of the arc in different offline time are collected
thereby
the characteristics of the offline arc are statistically analyzed. The results show that
under the circumstance of static pantograph-catenary offline
the arcing time is
between 15 ms and 25 ms and when the offline occurs in the rising section of the voltage amplitude(1
5
ms
11
1
5 ms)
not only the relative light intensity of the arc is stronger
but also the harmonics content of the voltage are more abundant. On the other hand
under the circumstance of dynamic pantograph-catenary offline
the arcing time is between 1 ms and 8 ms and when the offline occurs in the rising section of the voltage
the arcing time is shorter and the harmonics content of the voltage amplitude is lower than those in the dropping section. In conclusion
the static and dynamic pantograph-catenary offline has different degrees of influence on the electrical characteristics
arcing time
relative light intensity and harmonic content of the arc respectively.
Experimental Studies on Application Characteristics of Lightning Protection for Long Rod Suspension Composite Insulators for High-speed Railway Catenary
Method of Lightning Hazard Risk Evaluation for Traction Electric Network of High-speed Railway
Attracted Lightning Characteristics of High-speed Railway Catenary Based on Leader Propagation Model
Grounding Impedance and Current Dispersed Characteristics of High-speed Railway Integrated Grounding System
Lightning Overvoltage and Protection Measures of High-speed Railway Feeder Cable
Related Author
CHEN Kang
BIAN Kai
CHEN Weijiang
SHEN Haibin
ZHOU Ziqiang
WANG Tao
LU Zejun
ZHAO Chun
Related Institution
Shandong Xunshi Electric Co., Ltd.
Beijing Power Economic Research Institute
State Grid Corporation of China
China Electric Power Research Institute
Wuhan NARI Limited Liability Company, State Grid Electric Power Research Institute