Improved Method for Calculating the Number of Independent Stirrer Positions in Reverberation Chamber
|更新时间:2025-12-08
|
Improved Method for Calculating the Number of Independent Stirrer Positions in Reverberation Chamber
Vol. 42, Issue 11, Pages: 3641-3650(2016)
作者机构:
军械工程学院电磁环境效应国家级重点实验室
作者简介:
基金信息:
DOI:
CLC:
Published Online:20 November 2016,
Published:2016
稿件说明:
移动端阅览
WEI Guanghui, MENG Lingyuan, ZHAO Yang, et al. Improved Method for Calculating the Number of Independent Stirrer Positions in Reverberation Chamber[J]. 2016, 42(11): 3641-3650.
DOI:
WEI Guanghui, MENG Lingyuan, ZHAO Yang, et al. Improved Method for Calculating the Number of Independent Stirrer Positions in Reverberation Chamber[J]. 2016, 42(11): 3641-3650.DOI:
Improved Method for Calculating the Number of Independent Stirrer Positions in Reverberation Chamber
In order to measure the effective independent information of data for received power accurately and evaluate the stirring efficiency scientifically in reverberation chamber
we have proposed a new method based on the information entropy to quantify the correlations between different stirrer position samples
which gives a good solution to the problem that the correlation quantization result is always overestimated by the traditional approach. Moreover
we have analyzed the issue of non-uniqueness of the correlation quantization result caused by the loss of dimension information when stirrers work in the asynchronous status. With multidimensional received power matrix constructed to calculate the correlation coefficients between different stirrer positions
the information of stirrer step modes and spatial locations is completely characterized
and the correlation coefficients calculating formula for one-dimensional array is extended to multidimensional matrix simultaneously. The uniqueness of the number of independent stirrer positions when the stirrers are in asynchronous operation is ensured by constructing the correlation coefficients matrix to calculate its Frobenius norm and solve the number of the independent stirrer positions. Both the theoretical analyses and experimental verification reveal that the problem of stirrer dimension information loss and independent positions overestimation in IEC 61000-4-21 standard can be solved with the application of the method proposed above
which also contributes to the uniqueness and accuracy of the calculation and give a scientific evaluation of the stirring efficiency in reverberation chamber.