Equivalent Test Method for Stray Magnetic Field Interference of Three-phase Heavy Current Transformer
|更新时间:2025-12-08
|
Equivalent Test Method for Stray Magnetic Field Interference of Three-phase Heavy Current Transformer
Vol. 42, Issue 11, Pages: 3651-3658(2016)
作者机构:
1. 清华大学电机工程与应用电子技术系电力系统及发电设备控制和仿真国家重点实验室
2. 北京云道智造科技有限公司
3. 国网四川省电力公司计量中心
作者简介:
基金信息:
DOI:
CLC:
Published Online:20 November 2016,
Published:2016
稿件说明:
移动端阅览
ZHAO Wei, XU Wenjia, LI Shisong, et al. Equivalent Test Method for Stray Magnetic Field Interference of Three-phase Heavy Current Transformer[J]. 2016, 42(11): 3651-3658.
DOI:
ZHAO Wei, XU Wenjia, LI Shisong, et al. Equivalent Test Method for Stray Magnetic Field Interference of Three-phase Heavy Current Transformer[J]. 2016, 42(11): 3651-3658.DOI:
Equivalent Test Method for Stray Magnetic Field Interference of Three-phase Heavy Current Transformer
We put forward a stray flux test method for the heavy current transform(HCT) in a three-phase horizontal alignment bus system
based on the magnetic field synthesis of both the eccentric bus current and the return bus current to calculate the stray flux generated from external currents in a three-phase bus system. In the proposal
based on intensive analysis of numerical simulation results
a formula is obtained for solving the HCT stray flux and the maximum interference magnetic field. Under the formula
the mathematical model of the equivalent relationship between two types of magnetic field is given. Moreover
by solving the equation
we get the locating place of the eccentric and return buses. In order to evaluate the presented method
a real HCT has been taken as an example
the calculation results show that magnetic field curve and maximum HCT stray flux curve are consistent in shape
the presented method can accurately and effectively simulate the stray flux of the HCT in a three-phase bus system.