Comparison of PD Characteristics for Inverter-fed Motor Insulation Under Inusoidal and Repetitive Square Wave Voltage Conditions
|更新时间:2025-12-08
|
Comparison of PD Characteristics for Inverter-fed Motor Insulation Under Inusoidal and Repetitive Square Wave Voltage Conditions
Vol. 42, Issue 12, Pages: 3895-3900(2016)
作者机构:
四川大学电气信息学院
作者简介:
基金信息:
DOI:
CLC:
Published Online:31 December 2016,
Published:2016
稿件说明:
移动端阅览
WANG Peng, ZHOU Wanya, WANG Kejing, et al. Comparison of PD Characteristics for Inverter-fed Motor Insulation Under Inusoidal and Repetitive Square Wave Voltage Conditions[J]. 2016, 42(12): 3895-3900.
DOI:
WANG Peng, ZHOU Wanya, WANG Kejing, et al. Comparison of PD Characteristics for Inverter-fed Motor Insulation Under Inusoidal and Repetitive Square Wave Voltage Conditions[J]. 2016, 42(12): 3895-3900.DOI:
Comparison of PD Characteristics for Inverter-fed Motor Insulation Under Inusoidal and Repetitive Square Wave Voltage Conditions
The partial discharge(PD) test system is set up based on ultra-high frequency technologies in order to study PD characteristics for inverter-fed motor insulation under both sinusoidal and repetitive square wave voltage conditions. Resorting to the system
we performed PD tests on single discharge models made up of enameled wires used in low-voltage inverter-fed motor insulation under sinusoidal and repetitive square wave voltage with 200 ns rise times. Moreover
we analyzed single PD pulse magnitude
phase distribution in time domain
energy distribution in frequency domain
and the statistical PD patterns. Conclusions can be drawn that repetitive square wave and sinusoidal voltages having same peak-to-peak voltage and frequency can produce PD with significantly different magnitude
phase
and energy distribution as well as endurance lifetime. The PD magnitude and insulation endurance under repetitive square wave voltages are around 10 times and 1/3 times of those at sinusoidal voltages. Therefore
when performing insulation evaluation on inverter-fed motors according to standards released by International Electrotechnical Commission
PD and endurance test system should be considered carefully on the basis of the influence of repetitive square wave voltage parameters on PD and endurance characteristics.