Experience of Upgrading Electrostatic Precipitators for Ultra-low Emission from Coal-fired Power Plants
|更新时间:2025-12-08
|
Experience of Upgrading Electrostatic Precipitators for Ultra-low Emission from Coal-fired Power Plants
Vol. 43, Issue 2, Pages: 487-492(2017)
作者机构:
1. 神华国华电力公司
2. 神华国能集团有限公司
作者简介:
基金信息:
DOI:
CLC:
Published Online:10 February 2017,
Published:2017
稿件说明:
移动端阅览
XIAO Chuangying, WANG Shilong, HAN Ping. Experience of Upgrading Electrostatic Precipitators for Ultra-low Emission from Coal-fired Power Plants[J]. 2017, 43(2): 487-492.
DOI:
XIAO Chuangying, WANG Shilong, HAN Ping. Experience of Upgrading Electrostatic Precipitators for Ultra-low Emission from Coal-fired Power Plants[J]. 2017, 43(2): 487-492.DOI:
Experience of Upgrading Electrostatic Precipitators for Ultra-low Emission from Coal-fired Power Plants
The electrostatic precipitator(ESP) upgrading is highly demanded for ultra-low emission from coal-fired flue gas. The particle emission can only be controlled by increasing ESP length or height under the guide of revised Deutsch Equation
traditionally. However
by adopting ESP index
the product of average
peak electrical strength
and specific collection area
particle emission can also be reduced by increasing operating voltage and current. The final dust emission can be limited under 10 mg/m3 by a series of upgrading steps: replacement of single-phase power source by three-phase power source
flue gas cooling under 110 ℃
mixed rapping with side-rapping for front-side fields and top-rapping for end-side fields
integration of desulfurization devices and ESPs
etc. Besides
replacement of fabric filter by ESP can prevent the clogging of filters and limit the visible near-stack plumes and acid aerosol mists while reducing particle emission.