Online Detection Investigation of the High Voltage Shunt Reactor Winding Deformation Based on Coupling Injection of Pulses
|更新时间:2025-12-08
|
Online Detection Investigation of the High Voltage Shunt Reactor Winding Deformation Based on Coupling Injection of Pulses
Vol. 43, Issue 3, Pages: 872-878(2017)
作者机构:
1. 国网新疆电力公司
2. 国网电力科学研究院
3. 重庆大学输配电装备及系统安全与新技术国家重点实验室
作者简介:
基金信息:
DOI:
CLC:
Published Online:10 March 2017,
Published:2017
稿件说明:
移动端阅览
WANG Jian, ZHANG Guangzhou, ZHAO Xiaozhen, et al. Online Detection Investigation of the High Voltage Shunt Reactor Winding Deformation Based on Coupling Injection of Pulses[J]. 2017, 43(3): 872-878.
DOI:
WANG Jian, ZHANG Guangzhou, ZHAO Xiaozhen, et al. Online Detection Investigation of the High Voltage Shunt Reactor Winding Deformation Based on Coupling Injection of Pulses[J]. 2017, 43(3): 872-878.DOI:
Online Detection Investigation of the High Voltage Shunt Reactor Winding Deformation Based on Coupling Injection of Pulses
The online detection of winding deformations is seldomly investigated so far.Therefore
we proposed a detection method system of the high voltage shunt reactor winding deformation based on the impulse coupling injecting analysis
and the corresponding system is developed.Then
the detection system is verified and installed in 750 k V high voltage shunt reactor of a certain substation.It is concluded from the obtained frequency response characteristics of threephase high-voltage shunt reactors that the response voltage of 300 m V can be obtain under the excitation pulse voltage of 500 V; and the fingerprint data are obtained to provide the basis of the condition monitoring and warning of the windings.The reliable operation of power grid will be promoted if the proposed method is applied widely.
Time-domain Capacitance Current Compensation Algorithm with Shunt Reactors
Heat Dissipation Performance of Ultra-high Voltage Shunt Reactor with Sound Insulation Based on Finite Element Method
On-site Partial Discharge Test Method of 750 kV Shunt Reactor in High Altitude Area
The Single-phase Adaptive Reclosure Applicability Analysis and Fault Identification Method of Transmission Lines with Shunt Reactors Including DC Infeed
Related Author
ZHANG Jianan
JIAO Jinrong
RONG Yajun
LIN Feifei
ZANG Huaiquan
LI Jinzhong
LIU Yaqing
HUANG Qinqing
Related Institution
School of Electrical Engineering, Yanshan University
China Electric Power Research Institute
School of Electrical and Electronic Engineering, Huazhong University of Science and Technology
School of Electrical Engineering, Xi’an Jiaotong University
Electric Power Research Institute, State Grid Qinghai Electric Power Company