Analysis of the Insulation Characteristic of CF3I Ternary Gas Mixture Using Boltzmannês Equation
|更新时间:2025-12-08
|
Analysis of the Insulation Characteristic of CF3I Ternary Gas Mixture Using Boltzmannês Equation
Vol. 43, Issue 3, Pages: 721-726(2017)
作者机构:
1. 国家电网公司运维检修部
2. 国网电力科学研究院武汉南瑞有限责任公司
3. 华中科技大学强电磁工程与新技术国家重点实验室
作者简介:
基金信息:
DOI:
CLC:
Published Online:10 March 2017,
Published:2017
稿件说明:
移动端阅览
XU Lingling, CHENG Lin, DU Weijie, et al. Analysis of the Insulation Characteristic of CF3I Ternary Gas Mixture Using Boltzmannês Equation[J]. 2017, 43(3): 721-726.
DOI:
XU Lingling, CHENG Lin, DU Weijie, et al. Analysis of the Insulation Characteristic of CF3I Ternary Gas Mixture Using Boltzmannês Equation[J]. 2017, 43(3): 721-726.DOI:
Analysis of the Insulation Characteristic of CF3I Ternary Gas Mixture Using Boltzmannês Equation
摘要
CF3I气体作为潜在的SF
6
替代气体
为了解CF3I三元混合气体的临界击穿强度和协同效应
通过求解两项近似Boltzmann方程
计算得出CF3I三元混合气体在折合场强范围为100
5
00Td的电子能量分布函数(electron energy distribution function
EEDF)、有效电离系数?、临界折合场强(E/N)cr
采用系数ξ分析三元混合气体间的协同效应。计算结果表明
三元混合气体中如果存在N
2
或CO
2
等缓冲气体
EEDF中的低能电子分布增加
导致协同效应的出现。CF3I与N
2
和CO
2
的协同效应较明显
与CF4不存在协同效应。两种强电负性气体CF3I/SF
6
混合后会出现微弱的负协同效应
而添加N
2
或CO
2
能减轻负协同效应的影响。
Abstract
As a potential alternative gas of SF
6
CF
3
I is focused on.We calculated the electron energy distribution function(EEDF)
normalized effective ionization coefficient
and critical reduced electric field of CF
3
I ternary gas mixtures by using two-term approximate Boltzmann equation.Meanwhile
we analyzed the synergetic effect of gas mixtures.The results show that the addition of buffer gas such as N
2
or CO
2
in CF
3
I ternary gas mixtures helps to increase the number of electron in low energy and leads to the synergetic effect.Moreover