Determination and Analysis of Soluble Anions in Insulator Contamination by Capillary Ion Chromatography
|更新时间:2025-12-08
|
Determination and Analysis of Soluble Anions in Insulator Contamination by Capillary Ion Chromatography
Vol. 43, Issue 4, Pages: 1296-1301(2017)
作者机构:
国网山东省电力公司电力科学研究院
作者简介:
基金信息:
DOI:
CLC:
Published Online:10 April 2017,
Published:2017
稿件说明:
移动端阅览
ZHANG Yan, TANG Xinjian, ZHANG Yong, et al. Determination and Analysis of Soluble Anions in Insulator Contamination by Capillary Ion Chromatography[J]. 2017, 43(4): 1296-1301.
DOI:
ZHANG Yan, TANG Xinjian, ZHANG Yong, et al. Determination and Analysis of Soluble Anions in Insulator Contamination by Capillary Ion Chromatography[J]. 2017, 43(4): 1296-1301.DOI:
Determination and Analysis of Soluble Anions in Insulator Contamination by Capillary Ion Chromatography
To detect the soluble anions in insulator contamination accurately
a method based on capillary ion chromatography was put forward.The separation was achieved on IonP ac AS18 capillary anions analytical column with optimized KOH gradient elution and 0.4μL injection at 10μL/min after the proper pretreatment
and then the analytes were detected by suppressed conductivity.The external standard calibration curve was used for the quantitative analysis.Under the chosen conditions
the linear correlation coefficients were greater than 99.9%.The detection of limit with S/N=3 was in the range of 0.22
2
4.27μg/L
and the average r
ecoveries were in the range of 88.2%
1
01.0%.Hence
this method has better repeatability and accuracy
and is very suitable for the determination of soluble anions in insulator contamination.It is proved that isocratic elution could cause the error for the detection of soluble anions in insulator contamination.Moreover
it was conformed that NO
2
-
was not found in insulator contamination in Shandong area by this method.Except F
-
Cl
-
SO
4
2-
NO
3
-
PO
4
3-
C
2
O
4
2-
was detected and the content could not be ignored
which might be related to the increase in the emission of pollutants in the atmosphere.
Establishment of Key Parameter System for Condition Evaluation of Transmission Line Based on Association Rules and Principal Component Analysis
Health Effects of Extremely Low Frequency Electromagnetic Fields
Analysis and Prospect of Lightning Shielding Failure Evaluation Methods of Transmission Lines
Mechanism and Application of Lightning Protection Gap Extinguishing Power Frequency Arc Assisted by Explosion Shock Wave
Related Author
MIAO Xiren
CHEN Jing
HUANG Shicong
LIU Xinyu
HE Hao
JIANG Hao
CHEN Yufeng
YAN Yingjie
Related Institution
福州大学电气工程与自动化学院
Maintenance and Test Center of Ultra High Voltage Company of South Grid
Electric Power Research Institute of Shandong Power Supply Company of State Grid
Department of Electrical Engineering, Shanghai Jiao Tong University
Research Group of Biophysics and Medical Engineering, Zhejiang Provincial Key Laboratory of Bioelectromagnetics,School of Medicine, Zhejiang University