Phenomenon of Secondary Discharge on the High Voltage Ga As Solar Array in Geosynchronous Orbit
|更新时间:2025-12-08
|
Phenomenon of Secondary Discharge on the High Voltage Ga As Solar Array in Geosynchronous Orbit
Vol. 43, Issue 8, Pages: 2614-2619(2017)
作者机构:
1. 兰州空间技术物理研究所
2. 中国电子科技集团公司第十八研究所
作者简介:
基金信息:
DOI:
CLC:
Published Online:31 August 2017,
Published:2017
稿件说明:
移动端阅览
LIU Qing, LI Cunhui, QIN Xiaogang, et al. Phenomenon of Secondary Discharge on the High Voltage Ga As Solar Array in Geosynchronous Orbit[J]. 2017, 43(8): 2614-2619.
DOI:
LIU Qing, LI Cunhui, QIN Xiaogang, et al. Phenomenon of Secondary Discharge on the High Voltage Ga As Solar Array in Geosynchronous Orbit[J]. 2017, 43(8): 2614-2619.DOI:
Phenomenon of Secondary Discharge on the High Voltage Ga As Solar Array in Geosynchronous Orbit
The high voltage(HV) component can be a single fault-source accounted for the failure of the whole satellite. A reliable component is of great significance for the operation safety of spacecraft in orbit. The charging and discharging(C&D) process of the HV components will lead to the secondary discharge
therefore it becomes a key factor that constrains the development of the satellites as well as the operation safety. We studied the evaluation methods and the protection techniques for the secondary discharge of high voltage Ga As solar cell arrays(HV Ga As)
which is of great value to securing the on-orbit satellite operation safety. In order to study the HV Ga As solar cell array secondary discharge phenomenon of the damage caused by the satellite
gallium arsenide solar cell array through ground simulation of high pressure on-orbit actually charged environment
we resembled the HV Ga As solar cell array in the next electrostatic discharge and the second discharge process
and studied the passive protection methods
different structure size high pressure gallium arsenide solar cell array of charge and discharge performance. Research results show that the local charge imbalance is caused by HV Ga As solar cell array sample and an electrostatic discharge
and three junction Ga As high-pressure solar cell array samples in the absence of the room temperature vulcanized silicone rubber(RTV) under 80 V working voltage triggered secondary discharge events will break down high voltage permanent solar cell array series circuit short circuit. Coated RTV can decrease the high pressure Ga As solar cell array number of an electrostatic discharge generated by discharge and the discharge energy