Development of Test Device of Controllable Phase for Synergy of Power Frequency Voltage and Impulse Voltage
|更新时间:2025-12-08
|
Development of Test Device of Controllable Phase for Synergy of Power Frequency Voltage and Impulse Voltage
Vol. 44, Issue 3, Pages: 750-755(2018)
作者机构:
1. 四川大学电气信息学院
2. 西安交通大学电力设备电气绝缘国家重点实验室
3. 国网四川省电力公司电力科学研究院
作者简介:
基金信息:
DOI:
CLC:
Published Online:30 March 2018,
Published:2018
稿件说明:
移动端阅览
ZHOU Kai, HE Min, XIONG Qing, et al. Development of Test Device of Controllable Phase for Synergy of Power Frequency Voltage and Impulse Voltage[J]. 2018, 44(3): 750-755.
DOI:
ZHOU Kai, HE Min, XIONG Qing, et al. Development of Test Device of Controllable Phase for Synergy of Power Frequency Voltage and Impulse Voltage[J]. 2018, 44(3): 750-755.DOI:
Development of Test Device of Controllable Phase for Synergy of Power Frequency Voltage and Impulse Voltage
仿真结果表明:耦合电容值的大小影响作用于被试品上的工频电压和冲击电压的波形和效率。实测结果表明:该装置的硬件延迟时间为1.4 ms
工频与冲击电压的叠加相位可控
叠加波形与系统实测过电压波形类似
能够较好地模拟实际过电压。
Abstract
Overvoltage of distribution network is usually superimposed on the power frequency voltage
therefore
to simulate the actual overvoltage situation in the electrical power system
a test device of controllable phase for synergy of the power frequency voltage and the impulse voltage was designed. The coupling capacitor between the power frequency voltage generating circuit and impulse voltage generator can make the impulse voltage to superimpose on the power frequency voltage
and the automatic ignition device can control the phase of the power frequency voltage superimposed the impulse voltage. Moreover
the circuit principle of the device was analyzed and was simulated by using the ATP-EMTP software.The simulation results show that coupling capacitance value will affect the power frequency voltage and impulse voltage waveforms and efficiency. The experimental results show that the hardware delay time of the device is 1.4 ms
the superimposed phase of the power frequency voltage and the impulse voltage is controllable
and the superimposed waveforms are similar to the measured overvoltage waveforms which can simulate the actual overvoltage.
Non-contact Overvoltage Monitoring Sensor Based on Electro-optic Effect
Online Detecting Winding Deformation of Power Transformer Based on Transient Overvoltage
Influence of the Construction Modes of Lightning Conductor on the Lightning Protection Performance of Back Striking in the Contact Network Under Auto-transformer Power Supply Mode
Fault Diagnose Technology of Transformers Based on Inductive Oscillating Switching Impulse Voltage Withstand Test
Lightning Transient Analysis of Offshore Wind Turbine Based on ATP-EMTP
Related Author
HAN Rui
YUAN Tao
SIMA Wenxia
CHEN Shaoqing
DONG Heng
YANG Qing
LI Zhaojiong
CHEN Xiaohan
Related Institution
State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University
Electric Power Research Institute, State Grid Sichuan Electric Power Company
School of Electrical Engineering, Southwest Jiaotong University
School of Electrical Engineering, Xi’an Jiaotong University
Electric Power Research Institute of Guangdong Power Grid Co., Ltd.