Dose Effect of High Frequency Nanosecond Pulse Bursts on Muscle Contraction of Rabbit in Vivo
In order to explore the dose effect of high frequency nanosecond pulse bursts on muscle contraction
we investigated the effect of 10 unipolar high frequency nanosecond pulse bursts with different electric field intensities(1 kV/cm
4 kV/cm and 8 kV/cm)
intra-burst frequencies(10 kHz
100 kHz and 1 MHz) and intra-burst number of pulses(1
10 and 100) on rabbit muscle contraction in vivo. High frequency nanosecond pulse bursts with different parameters were delivered to the surface skin of rabbit thighs biceps through plate electrode
and the intensity of muscle contraction was assessed using the acceleration signal measured by a three-axis acceleration sensor attached on the surface skin of the muscle. The results of time and frequency domain analysis of synthetic acceleration module value signal show that the peak value of the signal increases as the value of any of the three parameters increases
however
the spectral distributions of the signals are similar
mainly distributing below 60 Hz. The multivariate nonlinear regression analysis of the experimental results reveals that the peak value of the signal can be expressed as a function of the three parameters
which indicate that when the frequency of the applied pulse burst is relatively low
appropriate increase in the intra-burst number of pulses will not strengthen muscle contraction too much. However
the intra-burst number of pulses should be minimized to limit strength of muscle contraction as much as possible when the frequency within the applied pulse burst is relatively high.
Experimental Study on Energy Coupling From Lightning to Wind Turbines Based on Artificial Triggered Lightning
Related Author
SHI Guangquan
ZHANG Yijun
CHEN Shaodong
ZHANG Yang
ZHENG Dong
Related Institution
Collaborative Innovation Center on Forecast and Evaluation of Meteorological Disasters (CIC-FEMD)/Key Laboratory for Aerosol-Cloud–Precipitation of China Meteorological Administration, Nanjing University of Information Science and Technology
State Key Laboratory of Severe Weather,Chinese Academy of Meteorological Sciences
Institute of Atmospheric Sciences, Fudan University
Guangzhou Institute of Tropical and Marine Meteorology,China Meteorological Administration