Precise Positioning Technology of Wild Fire Nearby Transmission Lines by Visible And Infrared Vision
|更新时间:2025-12-08
|
Precise Positioning Technology of Wild Fire Nearby Transmission Lines by Visible And Infrared Vision
Vol. 44, Issue 8, Pages: 2548-2555(2018)
作者机构:
国网湖南省电力公司防灾减灾中心电网输变电设备防灾减灾国家重点实验室
作者简介:
基金信息:
DOI:
CLC:
Published Online:31 August 2018,
Published:2018
稿件说明:
移动端阅览
HE Lifu, LU Jiazheng, LIU Yu, et al. Precise Positioning Technology of Wild Fire Nearby Transmission Lines by Visible And Infrared Vision[J]. 2018, 44(8): 2548-2555.
DOI:
HE Lifu, LU Jiazheng, LIU Yu, et al. Precise Positioning Technology of Wild Fire Nearby Transmission Lines by Visible And Infrared Vision[J]. 2018, 44(8): 2548-2555.DOI:
Precise Positioning Technology of Wild Fire Nearby Transmission Lines by Visible And Infrared Vision
which seriously threatens the security and stability of power grid. Consequently
on the basis of binocular stereo visions
we studied a positioning technology of wild fire nearby transmission lines by using the visible and infrared camera of the distributed wild fire monitoring device. A flame identification model for visible images was established based on HSV(Hue
Saturation
Value)color space. And a method of positioning for wild fire nearby transmission lines based on visible and infrared stereo vision was proposed. Taking the center of flame as the feature point of stereo matching
the method overcomes the problem of heterogeneous asynchronous binocular flame image matching. And the automatic measurement of fire to camera distance is realized.Moreover
we established a coordinate system based on the rotation center of the head
and put forward an accurate calculation method of the shortest distance from the fire to the transmission lines. This omits the problem of calibrating the external parameters of the camera outdoors
and the accurate positioning of the wildfire relative to the transmission line is achieved. Finally
through the experimental study
the feasibility and validity of the proposed method are verified. In the range of 500 meters
the measurement error of the distance from the fire to the camera is less than 6.6%
which can meet the practical application requirements. The research is of great significance to realize the automatic judgment of fire hazard level of transmission lines.
Establishment of Key Parameter System for Condition Evaluation of Transmission Line Based on Association Rules and Principal Component Analysis
Health Effects of Extremely Low Frequency Electromagnetic Fields
Analysis and Prospect of Lightning Shielding Failure Evaluation Methods of Transmission Lines
Mechanism and Application of Lightning Protection Gap Extinguishing Power Frequency Arc Assisted by Explosion Shock Wave
Related Author
MIAO Xiren
CHEN Jing
HUANG Shicong
LIU Xinyu
HE Hao
JIANG Hao
CHEN Yufeng
YAN Yingjie
Related Institution
福州大学电气工程与自动化学院
Maintenance and Test Center of Ultra High Voltage Company of South Grid
Electric Power Research Institute of Shandong Power Supply Company of State Grid
Department of Electrical Engineering, Shanghai Jiao Tong University
Research Group of Biophysics and Medical Engineering, Zhejiang Provincial Key Laboratory of Bioelectromagnetics,School of Medicine, Zhejiang University