Dynamic Reactive Power Compensation Configuration Method for Reducing the Risk of Commutation Failure in Multi-infeed DC System
|更新时间:2025-12-08
|
Dynamic Reactive Power Compensation Configuration Method for Reducing the Risk of Commutation Failure in Multi-infeed DC System
Vol. 44, Issue 10, Pages: 3258-3265(2018)
作者机构:
武汉大学电气工程学院
作者简介:
基金信息:
DOI:
CLC:
Published Online:31 October 2018,
Published:2018
稿件说明:
移动端阅览
ZHOU Shihao, TANG Fei, LIU Dichen, et al. Dynamic Reactive Power Compensation Configuration Method for Reducing the Risk of Commutation Failure in Multi-infeed DC System[J]. 2018, 44(10): 3258-3265.
DOI:
ZHOU Shihao, TANG Fei, LIU Dichen, et al. Dynamic Reactive Power Compensation Configuration Method for Reducing the Risk of Commutation Failure in Multi-infeed DC System[J]. 2018, 44(10): 3258-3265.DOI:
Dynamic Reactive Power Compensation Configuration Method for Reducing the Risk of Commutation Failure in Multi-infeed DC System
In order to prevent behaviors of simultaneous commutation failure in the multi-infeed DC system
we proposed a dynamic VAR configuration method for reducing the risk of DC commutation failure to optimize the type
location and capacity of the dynamic reactive power compensation device. Firstly
the impedance matrix of the system nodes and the DC distance coupling index were calculated to identify the weak areas of reactive power compensation and the set of critical faults. The index of commutation failure duration shortening effect and the sensitivity index were calculated by time domain simulation. Therefore
the candidate nodes could be selected based on these indexes. Seocndly
after establishing the reactive power allocation optimization model of reducing the risk of DC commutation failure
we could obtain the Pareto optimal solution set by the MOEA/D. Finally
the close degrees of every decision schemes were calculated by the entropy weight method. And based on the calculation results
the relative superiorities of decision schemes were assessed which can help the operators to choose the effective compromise solutions. Calculation results of actual power grid show that the risk of simultaneous commutation failure of multi-infeed HVDC can be better reduced by simultaneously optimizing the type
location and capacity of the dynamic reactive power compensation devices. The results provide references for dynamic reactive power compensation of the multi-infeed DC system.
Influence of Transition Resistance on Transient Power Converse in UHV AC/DC Hybrid Power System
Impact and Suppression Measures of Repeated and Simultaneous Commutation Failure in Multiple HVDC Power Transmission System Between Two Regional Power Grids
Dual-stage Method for Islanding Surface Searching Under Interconnected Power System
Influence of Suspension Patterns of UHVDC Line Composite Insulator on Its Impulse Flashover Characteristics
Surface Charge Accumulation on Insulators in SF6 and Its Effects on the Flashover Characteristics of HVDC GIL
Related Author
LIU Kezhen
LIANG Songtao
SHU Hongchun
LUO Xiao
WU Weimin
LIU Huagang
LIU Bing
CHEN Zhao
Related Institution
Faculty of Electric Power Engineering, Kunming University of Science and Technology
Central China Branch of State Grid Corporation of China
State Grid Henan Electric Power Company
Electric Power Research Institute,China Southern Power Grid Co., Ltd.
School of Electric Power, South China University of Technology