Are-extinguishing Mechanism on Multilateral Self-expanding Stream of Are-extinguishing Lightning Protection Gap
|更新时间:2025-12-08
|
Are-extinguishing Mechanism on Multilateral Self-expanding Stream of Are-extinguishing Lightning Protection Gap
Vol. 44, Issue 12, Pages: 3896-3902(2018)
作者机构:
1. 广西大学电气工程学院
2. 国网新疆电力公司塔城供电公司
作者简介:
基金信息:
DOI:
CLC:
Published Online:31 December 2018,
Published:2018
稿件说明:
移动端阅览
WANG Jufeng, LI Shirong, GUO Kezhu, et al. Are-extinguishing Mechanism on Multilateral Self-expanding Stream of Are-extinguishing Lightning Protection Gap[J]. 2018, 44(12): 3896-3902.
DOI:
WANG Jufeng, LI Shirong, GUO Kezhu, et al. Are-extinguishing Mechanism on Multilateral Self-expanding Stream of Are-extinguishing Lightning Protection Gap[J]. 2018, 44(12): 3896-3902.DOI:
Are-extinguishing Mechanism on Multilateral Self-expanding Stream of Are-extinguishing Lightning Protection Gap
In order to improve the performances of are-extinguishing lightning protection of intermediate and low-voltage power network lines and to reduce the trip-out rate
we developed a kind of self-expanding stream of arc-extinguishing lightning protection gap device
which is effective in inhibiting frequency arc. The gap
which can precisely position lightning discharge path
forces the arc column to form a segmentation. While it generates high pressure from the expansion of high-speed air
which strongly inhibits the development of transient power frequency wheeling arc
and ultimately extinguishes the arc. The formation mechanism of self-expanding stream was studied and self-expanding stream coupling power frequency arc mathematical mode was founded. A CFD software FLUENT was used to analyze the self-expanding stream airflow arc extinction. Moreover
experiments on arc-extinguishing lightning protection gap device were conducted
and the detailed process of arc extinguishing were recorded by using high-speed cameras. The actual operating results of the device on 10 kV distribution network lines were analyzed. The results show that the frequency freewheeling arc can be quickly extinguished by the self-expanding stream impaction
and lightning protection gap can significantly reduce the lightning trip-out rate to protect the safe and normal operation of the power grid with good usability.
Arc-extinguishing Test on Multiple Fracture Arc-extinguishing Lightning Protection Gap with Explosion Airflow
Analysis of Explosion Airflow Arc-extinguishing Test and Arc-extinguishing Temperature Simulation
Research on Arc-extinguishing Effectiveness of Arc-extinguishing Lightning Protection Gap Under the Action of High-speed Airflow
Simulation Analysis and Experimental Study on the Truncated Arc of an Are-extinguishing Lightning Protection Device Under the Action of Self-expanding Stream
Effectiveness Verification of Novel Air-blast Arc-quenching Device Based on Navier-Stokes Equations
Related Author
YAO Lina
QIU Hongbo
YAN Peng
CUI Guangzhao
GUO Wei
LIANG Xue
WU Dong
LI Guodong
Related Institution
Economic Research Institute,State Grid Henan Electric Power Company
College of Electricial and Information Engineering, Zhengzhou University of Light Industry
College of Energy and Electrical, Hehai University
School of Electrical Engineering, Guangxi University