摘要
针对目前国内外地面电场仪感应电流信号微弱、电磁干扰严重的问题
设计了一种新型双定子、差分式电场传感器。传感器感应到2路电流信号经过I/V转换器转为电压信号
通过减法器和50Hz工频陷波器消除共模干扰和工频干扰。光电开关传感器得到同步信号
采用相敏检波器对信号进行处理得到与场强成正比例关系的直流电压。经实验验证
该系统在-50~50 kV/m的模拟电场强度范围内
测量分辨力可达到10 V/m
线性度<1%。实际测量表明
差分式双定子结构和减法器有效消除了共模干扰
50Hz陷波器消除了工频干扰
高精度放大器提高了电场仪的测量精度。该系统能够实时测量大气电场的强度
并显示大气场强的变化曲线
可以为雷电监测预警提供必要的依据。
Abstract
In view of the weakness of induction current and the serious electromagnetic interference in the electric field instrument at home and abroad
we designed a new type of differential sensor with dual stator structure. Two current signals were sensed by the sensor and they were converted to voltage signals by passing through the I/V converter
and the common mode interference and the power frequency interference were eliminated by subtracting the instrument and the50 Hz power frequency notch filter. The synchronous signals were obtained by using photoelectric switch sensors
and a phase sensitive detector was used to process the signal to obtain a direct current voltage proportional to the field strength.The experimental results show that the resolution of the system is 10 V/m and linearity is less than 1% in the range of simulated field strength of-50~50 kV/m. The actual measurement results show that the differential double stator structure and the reducer can effectively eliminate the common mode interference
the 50 Hz trap filters can eliminate the power frequency interference
and the high precision amplifier can improve the measuring accuracy of electric field instrument.The system can measure the intensity of the atmospheric electric field in real time and show the curve of the field intensity of the atmosphere
which can provide a necessary basis for lightning monitoring and early warning.