Key Technology of Primary and Secondary Fusion of AC Voltage Sensor on Overhead Pole Mounted Switch in 12 kV Distribution Network
|更新时间:2025-12-08
|
Key Technology of Primary and Secondary Fusion of AC Voltage Sensor on Overhead Pole Mounted Switch in 12 kV Distribution Network
Vol. 45, Issue 9, Pages: 2818-2826(2019)
作者机构:
1. 中国电力科学研究院有限公司
2. 2. 上海固缘电力科技有限公司
作者简介:
基金信息:
DOI:
CLC:
Published Online:30 September 2019,
Published:2019
稿件说明:
移动端阅览
LI Shusen, SUN Zhiying. Key Technology of Primary and Secondary Fusion of AC Voltage Sensor on Overhead Pole Mounted Switch in 12 kV Distribution Network[J]. 2019, 45(9): 2818-2826.
DOI:
LI Shusen, SUN Zhiying. Key Technology of Primary and Secondary Fusion of AC Voltage Sensor on Overhead Pole Mounted Switch in 12 kV Distribution Network[J]. 2019, 45(9): 2818-2826.DOI:
Key Technology of Primary and Secondary Fusion of AC Voltage Sensor on Overhead Pole Mounted Switch in 12 kV Distribution Network
AC voltage sensor is the key component in the integration of primary and secondary equipment in a distribution network. Therefore
we carried out in-depth analysis and research on the AC voltage sensor technology which may be used as the primary and secondary fusion of equipment in distribution network. On the basis of the performance and characteristics of the AC voltage sensor based on the principle of impedance voltage division
the parameter analysis formula and determination principle of resistance voltage divider type
capacitance voltage divider type and resistance capacitance voltage divider type AC voltage sensor were deduced
respectively.Moreover
the parameter determination principle
error estimation formula and technical solution of error control were put forward
the rationality and feasibility of the proposed technical solution through rigorous derivation were demonstrated
and the simulation and tests were carried out. The research results show that
In order to eliminate the influence of stray capacitance to the ground
it is necessary to take good shielding measures for the resistance voltage divider type voltage sensors. However
it is difficult to take shielding measures because the sensors need to be encapsulated into the pole of the switch. The capacitance voltage-divider-type AC voltage sensors have advantages in anti-stray capacitance to ground
but are lacking in the transient characteristics.The sensors can be used as voltage sensors in primary and secondary fusion distribution network when equipped with special "impedance transformation" circuits. It is concluded that capacitance divider-type and paralleled-type resistance voltage-divider are suitable for primary and secondary fusion ac sensors.