Recovery Algorithm of Space Charge Measurement Signal by PEA Method for Plate Structures Under Temperature Gradient
|更新时间:2025-12-08
|
Recovery Algorithm of Space Charge Measurement Signal by PEA Method for Plate Structures Under Temperature Gradient
Vol. 45, Issue 10, Pages: 3335-3342(2019)
作者机构:
1. 上海交通大学电气工程系
2. 云南电网有限责任公司博士后工作站
作者简介:
基金信息:
DOI:
CLC:
Published Online:31 October 2019,
Published:2019
稿件说明:
移动端阅览
XU Jiaxuan, HU Jialei, WANG Yalin, et al. Recovery Algorithm of Space Charge Measurement Signal by PEA Method for Plate Structures Under Temperature Gradient[J]. 2019, 45(10): 3335-3342.
DOI:
XU Jiaxuan, HU Jialei, WANG Yalin, et al. Recovery Algorithm of Space Charge Measurement Signal by PEA Method for Plate Structures Under Temperature Gradient[J]. 2019, 45(10): 3335-3342.DOI:
Recovery Algorithm of Space Charge Measurement Signal by PEA Method for Plate Structures Under Temperature Gradient
To obtain the space charge distribution of electrical equipment under a temperature gradient
the one-dimensional cross-linked polyethylene(XLPE) plate samples were taken as examples. The voltage signals representing space charge distributions of XLPE samples under constant temperatures and temperature gradients were measured by a pulse electro-acoustic(PEA) method
then a new recovery algorithm of voltage-acoustic-space charge transformation was derived. The analyses of measured voltage signals characterizing space charge distributions under different constant temperatures indicated that the main components of acoustic in XLPE under temperature of 20~80 ℃ were within 0~35 MHz
and attenuation coefficient of acoustic signal in this range had a one-dimensional linear relationship with temperature. Based on this phenomenon
the transfer function calculation matrix of acoustic propagation process in traditional space charge recovery model under constant temperature was revised
and a new recovery algorithm for space charge measurement under temperature gradient was derived. According to recovery results of voltage signals for space charge in XLPE under different temperature gradients
space charge distributions in 5 kV/mm without significant charge accumulation was obtained. The accuracy of new recovery algorithm was verified by comparing the internal electrical distributions calculated by Poisson equation and theoretical value inside XLPE. Finally
the new recovery algorithm was used to measure and analyze the space charge in XLPE under DC field
and it was found that a temperature gradient led to significant decrease in space charge accumulation on the high temperature side as well as increase in field strength distortion on the low temperature side.