Analysis and Test of the High Current Forced Commutation Interruption Characteristics for a DC Vacuum Circuit Breaker
|更新时间:2025-12-08
|
Analysis and Test of the High Current Forced Commutation Interruption Characteristics for a DC Vacuum Circuit Breaker
Vol. 46, Issue 2, Pages: 603-609(2020)
作者机构:
武汉船用电力推进装置研究所船舶综合电力技术重点实验室
作者简介:
基金信息:
DOI:
CLC:
Published Online:29 February 2020,
Published:2020
稿件说明:
移动端阅览
PENG Zhendong, YANG Chenguang, LI Bo, et al. Analysis and Test of the High Current Forced Commutation Interruption Characteristics for a DC Vacuum Circuit Breaker[J]. 2020, 46(2): 603-609.
DOI:
PENG Zhendong, YANG Chenguang, LI Bo, et al. Analysis and Test of the High Current Forced Commutation Interruption Characteristics for a DC Vacuum Circuit Breaker[J]. 2020, 46(2): 603-609.DOI:
Analysis and Test of the High Current Forced Commutation Interruption Characteristics for a DC Vacuum Circuit Breaker
With the well flexibility to expand for medium & high voltage large power application
the DC vacuum circuit breaker(VCB) based on active forced current commutation is becoming a very important development direction for DC interruption technology. For a 10 kV DC VCB
lots of experimental studies for the high current commutation interruption(CCI) process were conducted after a further analysis of the CCI characteristics in this paper. The experimental results indicated that the VCB could not interrupt reliably at the current zeros for the peak arc current about 23 kA and the fall rate about 300 A/μs. In addition
some dispersion and randomness took place in the vacuum gap(VG) post-arc dielectric recovery(PADR) process. In order to improve the high current PADR characteristics
a DC VCB CCI scheme was proposed with a diode connected in series
which could provide a current zero interval for the high current vacuum arc through the diode reverse blocking. According to the comparative interruption test results under the same parameters
although the process of dielectric recovery
dielectric breakdown
dielectric recovery’ might be repeated continuously during the diode reverse blocking
the arc reigniting would not happen in the VG. Finally
the VG was able to built enough dielectric strength before the commutation capacitor voltage polarity becoming positive
so that reliable interruption of the high DC current could be realized. Meanwhile
under the test conditions
it would take at least 85 μs to completely recover the dielectric strength in the post-arc stage.