Restraint of Start-up Inrush Current of Three-phase VSI Based on Virtual Damping Control
There exists a start-up inrush current problem during the grid-connection period within the three-phase voltage-source inverters(VSI). Consequently
we propose a new method to suppress the inrush current effectively based on the virtual damping control. Firstly
a mathematical model is established based on the dq coordinate frame
and it is recognized that the primary cause of inrush current is the decrement in the damping ratio during the grid-connection period. Then
the detailed design process of the virtual damping control method is given
and the correctness and effectiveness of the proposed method are verified by simulation and experiments. The results show that the inrush current can be more than twice the rated current before adding virtual damping
the grid connection without inrush current can be realized after adding virtual damping
and it can also improve the robust stability of the system