Temperature Field Measurement of Long Air Gap Discharge Channel Based on Background Oriented Schlieren Technology
|更新时间:2025-12-08
|
Temperature Field Measurement of Long Air Gap Discharge Channel Based on Background Oriented Schlieren Technology
Vol. 46, Issue 4, Pages: 1234-1242(2020)
作者机构:
1. 华北电力大学河北省输变电设备安全防御重点实验室
2. 中国电力科学研究院有限公司
作者简介:
基金信息:
DOI:
CLC:
Published Online:30 April 2020,
Published:2020
稿件说明:
移动端阅览
GENG Jianghai, WANG Quansheng, Lü Fangcheng, et al. Temperature Field Measurement of Long Air Gap Discharge Channel Based on Background Oriented Schlieren Technology[J]. 2020, 46(4): 1234-1242.
DOI:
GENG Jianghai, WANG Quansheng, Lü Fangcheng, et al. Temperature Field Measurement of Long Air Gap Discharge Channel Based on Background Oriented Schlieren Technology[J]. 2020, 46(4): 1234-1242.DOI:
Temperature Field Measurement of Long Air Gap Discharge Channel Based on Background Oriented Schlieren Technology
The development process of long air gap discharge is accompanied by the phenomenon of dielectric thermal ionization. Accurate temperature field acquisition is conducive to the in-depth analysis of gap discharge characteristics. The background oriented schlieren(BOS) breaks through the limitation of lens size in traditional schlieren technology and can obtain the temperature distribution characteristics of large-scale discharge channels. In this paper
the background oriented schlieren measurement system is built
the background spot atlas in the development of discharge is collected
and the ray offset through the discharge channel is analyzed by PIV particle image velocimetry technology; the refractive index corresponding to the ray offset is calculated based on Abel inverse transformation
and then the density field and temperature field are reconstructed quantitatively according to the thermodynamic equation and ideal gas state equation. The temperature calibration of alcohol lamp flame is carried out
and the analysis results are basically consistent with the measured results of thermocouple. A 1 m rod plate air gap is taken as the research object
through the background schlieren measurement system
the development process of gap positive discharge is observed
and the temporal and spatial variation law of discharge channel temperature is analyzed. The results show that the temperature distribution of the cross section in the middle of the gap is about 1 200 K
and the temperature field is axisymmetric. The closer the channel is to the center
the greater the temperature gradient will be
and the temperature of the whole channel decreases gradually from the pole.