Intense Electric-field Sensor for Broad Temperature-range Applications Based on the Electro-optic Interferometer of Bulk Lithium Niobate
|更新时间:2025-12-08
|
Intense Electric-field Sensor for Broad Temperature-range Applications Based on the Electro-optic Interferometer of Bulk Lithium Niobate
Vol. 46, Issue 6, Pages: 1913-1921(2020)
作者机构:
1. 重庆大学输配电装备及系统安全与新技术国家重点实验室
2. 国网宁夏电力有限公司电力科学研究院
3. 云南电网有限责任公司电力科学研究院
作者简介:
基金信息:
DOI:
CLC:
Published Online:30 June 2020,
Published:2020
稿件说明:
移动端阅览
SUN Shangpeng, YANG Qing, HE Yanxiao, et al. Intense Electric-field Sensor for Broad Temperature-range Applications Based on the Electro-optic Interferometer of Bulk Lithium Niobate[J]. 2020, 46(6): 1913-1921.
DOI:
SUN Shangpeng, YANG Qing, HE Yanxiao, et al. Intense Electric-field Sensor for Broad Temperature-range Applications Based on the Electro-optic Interferometer of Bulk Lithium Niobate[J]. 2020, 46(6): 1913-1921.DOI:
Intense Electric-field Sensor for Broad Temperature-range Applications Based on the Electro-optic Interferometer of Bulk Lithium Niobate
the optical E-field sensor shows the advantages of large measurement amplitude and wide frequency range
but the weak temperature stability restricts its development and application. For this reason
the influence mechanism on temperature stability of E-field sensors using lithium niobate with the x-axis and z-axis propagation was analyzed in this paper. And the interferometric E-field sensor with the z-axis propagation which is suitable for a broad range of temperatures was proposed. A test platform was constructed to obtain the transfer function parameters of E-field sensor in a wide temperature range. Meanwhile
its basic characteristics was calibrated
including the temperature dependence of the linear measurement range
typical signal response and frequency response. The results show that the calibrated E-field sensor is able to keep stable in the wide temperature range of 0~50 ℃
and it is capable of measuring an electric fields of frequencies of 10 Hz~700 kHz and intensities of 5~ 600 kV/m
which can provide references for the practical application.