Analysis of Non-isolated Cascaded Dual-buck Grid-connected Inverter and Its Leakage Current Suppression
|更新时间:2025-12-08
|
Analysis of Non-isolated Cascaded Dual-buck Grid-connected Inverter and Its Leakage Current Suppression
Vol. 46, Issue 7, Pages: 2434-2445(2020)
作者机构:
1. 西南石油大学电气信息学院
2. 四川大学电气工程学院
作者简介:
基金信息:
DOI:
CLC:
Published Online:31 July 2020,
Published:2020
稿件说明:
移动端阅览
DAI Yunzhong, ZHANG Rongfei, XIE Kaiwen, et al. Analysis of Non-isolated Cascaded Dual-buck Grid-connected Inverter and Its Leakage Current Suppression[J]. 2020, 46(7): 2434-2445.
DOI:
DAI Yunzhong, ZHANG Rongfei, XIE Kaiwen, et al. Analysis of Non-isolated Cascaded Dual-buck Grid-connected Inverter and Its Leakage Current Suppression[J]. 2020, 46(7): 2434-2445.DOI:
Analysis of Non-isolated Cascaded Dual-buck Grid-connected Inverter and Its Leakage Current Suppression
To suppress the leakage current of traditional dual-buck grid-connected inverters
a novel non-isolated cascaded dual-buck grid-connected inverter topology(CDBGCI) and dual-carrier sinusoidal pulse width modulation(DCSPWM) strategy were proposed. The high-frequency and low-frequency common-mode equivalent models of CDBGCI were established by the method of common-mode equivalent circuit
and the high-frequency and low-frequency common-mode leakage currents of the inverters are analyzed in detail
respectively. The research results show the high-frequency common-mode voltage of the novel cascaded inverter keeps a constant value during a power frequency period
and the leakage current is less than 300 mA
so the high-frequency common-mode current is effectively suppressed. Meanwhile
compared with asymmetric CDBGCI
symmetric CDBGCI has a smaller low-frequency common-mode leakage current
and the high-frequency common-mode leakage current can be suppressed when n dual buck grid-connected inverters are cascaded. Finally
the results can provide references for the research of cascade grid-connected inverter topology and leakage current suppression.