Design of Ultra-high Frequency Antenna for Discharge Detection Under High Frequency Impulsive Voltage Conditions for Inverter-fed Motors Insulation
|更新时间:2025-12-08
|
Design of Ultra-high Frequency Antenna for Discharge Detection Under High Frequency Impulsive Voltage Conditions for Inverter-fed Motors Insulation
Vol. 46, Issue 10, Pages: 3451-3459(2020)
作者机构:
1. 四川大学电气工程学院
2. 西南电力设计院有限公司
作者简介:
基金信息:
DOI:
CLC:
Published Online:31 October 2020,
Published:2020
稿件说明:
移动端阅览
MA Shijin, WANG Peng, DONG Han, et al. Design of Ultra-high Frequency Antenna for Discharge Detection Under High Frequency Impulsive Voltage Conditions for Inverter-fed Motors Insulation[J]. 2020, 46(10): 3451-3459.
DOI:
MA Shijin, WANG Peng, DONG Han, et al. Design of Ultra-high Frequency Antenna for Discharge Detection Under High Frequency Impulsive Voltage Conditions for Inverter-fed Motors Insulation[J]. 2020, 46(10): 3451-3459.DOI:
Design of Ultra-high Frequency Antenna for Discharge Detection Under High Frequency Impulsive Voltage Conditions for Inverter-fed Motors Insulation
Due to the electromagnetic interference produced by the high frequency switching on/off of power electronic devices
the detection technology under sinusoidal condition cannot be used for the detection of partial discharge(PD) under impulsive voltages with fast rise times. In this paper
a microstrip Balun is added to realize impedance matching and a dielectric layer with high permittivity is loaded on the radiation surface of the antenna to optimize the antenna structure. The gain of the antenna is improved in high frequency bandwidth of 0.5~1.5 GHz and the signal-to-noise ratio is enhanced distinctly. Then
we studied the time-frequency statistical characteristics of PD under different square pulse voltage parameters and antenna placement distance by using the UHF antenna designed for PD detection under voltage with fast rise time. Experimental results show that the amplitude of UHF signal in the frequency domain of 0.5~1.3 GHz decreases non-linearly with the increase of antenna placement distance. The influence of voltage frequency on the high frequency components of the discharge is remarkable
and the PD signal decays seriously with the increase of frequency. Through the simulation and experimental verification of the antenna
the optimal parameters are obtained. The thicknesses of the dielectric cover is 1 mm
and the distance from the radiation surface of the antenna is d = 30 mm. The gain is greater than 2.5 dB in the 500~900 MHz frequency band
greater than 7.0 dB in the 900 MHz~2 GHz frequency band
and the standing wave ratio is less than 1.4. The results obtained in this study can provide references and theoretical supports for PD detection of inverter-fed motor under high-frequency pulse voltage.