Feature Extraction Method for Partial Discharge Pattern in GIS Based on Time-frequency Analysis and Fractal Theory
|更新时间:2025-12-08
|
Feature Extraction Method for Partial Discharge Pattern in GIS Based on Time-frequency Analysis and Fractal Theory
Vol. 47, Issue 1, Pages: 287-295(2021)
作者机构:
1. 中国石油大学(华东)新能源学院
2. 国网浙江省电力公司电力科学研究院
3. 3. 青岛睿能达电气技术有限公司
作者简介:
基金信息:
DOI:
CLC:
Published Online:30 January 2021,
Published:2021
稿件说明:
移动端阅览
CHEN Jiming, XU Chenhang, LI Peng, et al. Feature Extraction Method for Partial Discharge Pattern in GIS Based on Time-frequency Analysis and Fractal Theory[J]. 2021, 47(1): 287-295.
DOI:
CHEN Jiming, XU Chenhang, LI Peng, et al. Feature Extraction Method for Partial Discharge Pattern in GIS Based on Time-frequency Analysis and Fractal Theory[J]. 2021, 47(1): 287-295.DOI:
Feature Extraction Method for Partial Discharge Pattern in GIS Based on Time-frequency Analysis and Fractal Theory
Partial discharge(PD) pattern recognition is a critical indicator for evaluating the insulation state of electrical equipment. PD signals can be obtained by ultra high frequency(UHF) sensor. However
traditional methods based on statistical parameters have the disadvantages of high dimension and invalid information for signal feature extraction. In this paper
we propose a feature extraction method based on time-frequency analysis and fractal theory for partial discharge pattern recognition of gas insulated switchgear(GIS). Firstly
the wavelet transform is applied to extract the energy map of time-frequency distribution of partial discharge signals. Then
the differential box counting(DBC) is used to extract the fractal dimensions features of the energy distribution map
and the linear discriminant analysis(LDA) is used to reduce the dimension of the feature vectors. Finally
the support vector machine(SVM) is employed to classify the partial discharge defects. To evaluate the effectiveness of the proposed method in this paper
four typical types of defects
namely protrusion discharge
free moving particle discharge
surface discharge
and floating electrode discharge
have been set up in the 252 k V GIS model chamber of the laboratory. Partial discharge signals have been obtained by UHF sensors and classified by the proposed method. The experimental results show that the recognition accuracy rate for all the four typical discharge types exceeds 96% by using the proposed feature extraction method
which is significantly better than the traditional methods based on statistical parameters for signal feature extraction.