Negative Corona Discharge Characteristics of Needle-plate and Rod-plate Structures Under Different Temperatures
|更新时间:2025-12-08
|
Negative Corona Discharge Characteristics of Needle-plate and Rod-plate Structures Under Different Temperatures
Vol. 47, Issue 5, Pages: 1847-1856(2021)
作者机构:
1. 清华大学电机工程与应用电子技术系电力系统及发电设备控制和仿真国家重点实验室
2. 国网山西省电力公司经济技术研究院
作者简介:
基金信息:
DOI:
CLC:
Published Online:31 May 2021,
Published:2021
稿件说明:
移动端阅览
FENG Qikun, HUANG Lei, LIU Difan, et al. Negative Corona Discharge Characteristics of Needle-plate and Rod-plate Structures Under Different Temperatures[J]. 2021, 47(5): 1847-1856.
DOI:
FENG Qikun, HUANG Lei, LIU Difan, et al. Negative Corona Discharge Characteristics of Needle-plate and Rod-plate Structures Under Different Temperatures[J]. 2021, 47(5): 1847-1856.DOI:
Negative Corona Discharge Characteristics of Needle-plate and Rod-plate Structures Under Different Temperatures
The characteristics of corona discharge under actual conditions are closely related to the surrounding environmental conditions. In order to study the mechanism and law of the negative DC corona pulse characteristics with ambient temperature under different electrode shapes
a fluid dynamics model in which the influence of ambient temperature was taken into account was established in this paper
and the negative corona discharge model of needle-plate and rod-plate structure was calculated respectively. The rules that the Trichel pulse
electric field strength
electron density
pulse peak
pulse duration
and pulse frequency vary with environmental temperature were studied systematically. Through the calculation and analysis
it is found that the onset voltage of rod-plate model is lower
while the duration is longer. With the increase of ambient temperature
the value of pulse peak
pulse duration and pulse frequency will increase. Meanwhile
the electric field will be stronger in the discharge space and the movement of charged particles will be more rapid under higher temperature. Besides
the radius of curvature of the needle and rod electrode also affects the corona discharge
and the negative corona discharge is more intense when the radius of curvature is small.