Electrical Aging Characteristics of VPI Main Insulation of Large Generator Based on Thermally Stimulated Current
|更新时间:2025-12-08
|
Electrical Aging Characteristics of VPI Main Insulation of Large Generator Based on Thermally Stimulated Current
Vol. 47, Issue 5, Pages: 1780-1787(2021)
作者机构:
1. 哈尔滨大电机研究所
2. 水力发电设备国家重点实验室
3. 国家水力发电设备工程技术研究中心
4. 哈尔滨电机厂有限责任公司
5. 哈尔滨理工大学电介质工程国家重点实验室培育基地
作者简介:
基金信息:
DOI:
CLC:
Published Online:31 May 2021,
Published:2021
稿件说明:
移动端阅览
FU Qiang, SONG Yang, CHEN Qingguo, et al. Electrical Aging Characteristics of VPI Main Insulation of Large Generator Based on Thermally Stimulated Current[J]. 2021, 47(5): 1780-1787.
DOI:
FU Qiang, SONG Yang, CHEN Qingguo, et al. Electrical Aging Characteristics of VPI Main Insulation of Large Generator Based on Thermally Stimulated Current[J]. 2021, 47(5): 1780-1787.DOI:
Electrical Aging Characteristics of VPI Main Insulation of Large Generator Based on Thermally Stimulated Current
In order to study the electrical aging characteristics of main insulation of large generator stator bar
the thermally stimulated current(TSC) was used to research the main insulation properties of vacuum pressure impregnating(VPI)
the formation mechanism of TSC peak was analyzed
and the characteristic parameters of the TSC peak were calculated. Fourier transform infrared spectroscopy(FTIR) was used to analyze the group changes of the adhesive contained in the insulating material
and scanning electron microscopy(SEM) was used to observe the changes in material morphology in the microscopic state. The test results show that the TSC spectrum of VPI main insulation is a double-peak curve caused by turning polarization and interface polarization in measured range of -40~120 ℃
and the peak temperatures are at around -5 ℃ and 70 ℃. With the increase of electrical aging time
the activation energy of turning polarization peak decreases slightly
the interface polarization peak increases obviously
and the amplitude and release charge of each peak curve increase to different degrees. The results of this study lay the foundation for analyzing the aging mechanism of the main insulation of stator bar by using the TSC method.