Distribution Characteristics of Spatial Magnetic Field in UHV GIL Gallery in Short-circuit Fault Condition
|更新时间:2025-12-08
|
Distribution Characteristics of Spatial Magnetic Field in UHV GIL Gallery in Short-circuit Fault Condition
Vol. 47, Issue 5, Pages: 1866-1871(2021)
作者机构:
1. 电网环境保护国家重点实验室(中国电力科学研究院有限公司)
2. 国家电网有限公司
3. 合肥工业大学电气与自动化工程学院
作者简介:
基金信息:
DOI:
CLC:
Published Online:31 May 2021,
Published:2021
稿件说明:
移动端阅览
ZHAO Jun, CHEN Weijiang, BIAN Kai, et al. Distribution Characteristics of Spatial Magnetic Field in UHV GIL Gallery in Short-circuit Fault Condition[J]. 2021, 47(5): 1866-1871.
DOI:
ZHAO Jun, CHEN Weijiang, BIAN Kai, et al. Distribution Characteristics of Spatial Magnetic Field in UHV GIL Gallery in Short-circuit Fault Condition[J]. 2021, 47(5): 1866-1871.DOI:
Distribution Characteristics of Spatial Magnetic Field in UHV GIL Gallery in Short-circuit Fault Condition
A large magnetic field is generated in the UHV GIL gallery under short-circuit fault conditions
threatening the normal operation of the monitoring and communication equipment in the gallery. Based on the analysis of GIL short-circuit current conduction and magnetic field coupling process
a spatial magnetic field simulation model of Su-Tong UHV GIL integrated gallery is established in this paper. The calculation results show that the magnetic field at the end of the gallery is the largest(up to 10 mT) and decays rapidly towards the inside of the gallery. Thus
GIL gallery can be divided into port area
attenuation area
and near zero field area. Based on the calculation results
the magnetic field on the surface of the GIL supporting steel structure and the shell conductor of the gallery port area exceeds the immunity test value of 1 s to 3 s short-term power frequency magnetic field specified in standard GB/T 17626.8
so it is suggested that the weak current equipment such as monitoring and communication should be arranged far away from the gallery port area
especially the adjacent location of the shell conductor.
Measurement Method and System for Transient Platform Potential Rise and Electromagnetic Disturbance of Ultra-high Voltage Series Compensation Device
Numerical Calculation on Very Fast Transient Overvoltage of UHV Gas Insulated Substation by Variable Gap Arc Model
Analysis on Electromagnetic Compatibility Immunity Requirements for Secondary Equipment During Switching Transient Operations in Intelligent Substation
Conductive Interference Analysis and Anti-interference Methods of Electronic Transformers in Disconnector Switching Test
Related Author
WEN Xishan
LIU Chenlei
LI Wei
PAN Zhuohong
CAI Hansheng
HU Shangmao
MA Qiyan
CUI Xiang
Related Institution
China Southern Power Grid Electric Power Research Institute
School of Electrical Engineering, Wuhan University
EPRI Science and Technology Co. Ltd.
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University