Negative Sequence Compensation Model and Control Strategy of Electrified Railway With YNd Tansformer and SVG
|更新时间:2025-12-08
|
Negative Sequence Compensation Model and Control Strategy of Electrified Railway With YNd Tansformer and SVG
Vol. 47, Issue 5, Pages: 1740-1752(2021)
作者机构:
西南交通大学电气工程学院
作者简介:
基金信息:
DOI:
CLC:
Published Online:31 May 2021,
Published:2021
稿件说明:
移动端阅览
WANG Hui, LI Qunzhan, XIE Shaofeng, et al. Negative Sequence Compensation Model and Control Strategy of Electrified Railway With YNd Tansformer and SVG[J]. 2021, 47(5): 1740-1752.
DOI:
WANG Hui, LI Qunzhan, XIE Shaofeng, et al. Negative Sequence Compensation Model and Control Strategy of Electrified Railway With YNd Tansformer and SVG[J]. 2021, 47(5): 1740-1752.DOI:
Negative Sequence Compensation Model and Control Strategy of Electrified Railway With YNd Tansformer and SVG
A method of negative sequence compensation based on YNd transformer and static var generator is proposed from the perspective of compensation with active reactive power. The general mathematical model of negative sequence compensation is constructed; meanwhile
the YNd11 transformer is taken as an example
and the topology of negative sequence compensation is divided into compensation modes I and II based on the mathematical model. The mathematical models of reactive capacity and current of static var generator for cophase and out of phase power supply are constructed
respectively
and a method to determine the scheme of negative sequence compensation is proposed. A double-closed-loop control strategy for compensation modes I and II under the conditions of co-phase power supply and out-of-phase power supply is proposed
which can achieve the purposes of stabilizing voltage and ensuring response speed
and can realize satisfaction of compensation of negative sequence. By taking the data of a traction substation as an example
the determination method of the negative sequence compensation scheme is illustrated
and the results show that the proposed scheme can meet the requirements of the national standard on reducing the capacity of the compensation device. The effectiveness and accuracy of the control strategy of compensation mode I and II for the negative sequence compensation are verified by simulation.
Design and Implementation of MMC-DSTATCOM Control System
New Ice-melting Device with Function of Reactive Power Compensation and Active Filtering
Dynamic Voltage Security Analysis and Control Strategy for Wind Power Centralized System
Integrated Strategy for Low Voltage Ride Through of Doubly-fed Induction Generator
Topology and Control of High Power Current Source Converter SVG
Related Author
KANG Yong
FANG Wuping
DAI Ke
XU Chen
ZHU Yuan
TAN Yanjun
ZHANG Hongxian
LI Bo
Related Institution
State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology
State Key Laboratory of Disaster Prevention and Reduction for Power Transmission Equipment, Disaster Prevention and Reduction Center,State Grid Hunan Electric Company
State Key Laboratory of Operation and Control of Renewable Energy & Storage Systems, China Electric Power Research Institute
Electric Power Planning and Engineering Institute
Key Laboratory of Smart Grid of Ministry of Education, Tianjin University