Equalization Design of Isolated Power Supply Transformer for 200 kV DC Circuit Breaker
|更新时间:2025-12-08
|
Equalization Design of Isolated Power Supply Transformer for 200 kV DC Circuit Breaker
Vol. 47, Issue 6, Pages: 2124-2131(2021)
作者机构:
1. 先进输电技术国家重点实验室(全球能源互联网研究院有限公司)
2. 华北电力大学新能源电力系统国家重点实验室
作者简介:
基金信息:
DOI:
CLC:
Published Online:30 June 2021,
Published:2021
稿件说明:
移动端阅览
LIU Yuan, ZHANG Sheng, CUI Xiang, et al. Equalization Design of Isolated Power Supply Transformer for 200 kV DC Circuit Breaker[J]. 2021, 47(6): 2124-2131.
DOI:
LIU Yuan, ZHANG Sheng, CUI Xiang, et al. Equalization Design of Isolated Power Supply Transformer for 200 kV DC Circuit Breaker[J]. 2021, 47(6): 2124-2131.DOI:
Equalization Design of Isolated Power Supply Transformer for 200 kV DC Circuit Breaker
The isolated power supply transformer is the core equipment for high-voltage DC circuit breaker to obtain energy
which transmits power from ground potential to the DC circuit breaker in high-voltage DC lines and ensures reliable and stable operation of DC circuit breakers. The 200 kV DC high-voltage isolating transformer introduced in this paper is made up of four 50 kV transformers. Due to the distributed capacitance
the rated DC voltage and the transient over-voltage of the pole line are unevenly applied to the four transformers
which increases the risk of insulation failure of a single transformer. In order to solve the above problems
we analyzed the circuit of the high-voltage DC isolation transformer
extracted distributed capacitor parameters
and completed the design and parameter configuration of the voltage equalization scheme. On this basis
voltage percent deviation of four-stage isolation transformer could be controlled within ±5% through equalization design
which was verified by simulation analysis and tests. The research results show that the voltage equalization method with 200 M? resistor and 1 nF capacitor in parallel can meet the engineering design and operation requirements of high-voltage DC isolation transformer.
Online Detecting Winding Deformation of Power Transformer Based on Transient Overvoltage
Application of Current-source Hybrid Electro-mechanical DC Circuit Breaker in UHVDC Transmission Systems
Mechanism of Improving the Lighting Protection Performance of Back-flashover Due to Inductive Lightning Rod
Simulation and Test of Electromagnetic Interference with Electronic Current Transformer
Study on Fast Analysis Method Transient Fundamental Frequency Overvoltage of Wind Turbine Generators in Sending System when Serious Power Disturbances Occur in Large-capacity UHVDC
Related Author
YAO Chenguo
ZHAO Zhongyong
LI Chengxiang
CHEN Xiaohan
LI Zhaojiong
ZHENG Xu
DING Jianyong
ZHU Ruoxi
Related Institution
State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University
State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology
State Grid HBEPC Economic & Technology Research Institute
School of Electrical Engineering, Wuhan University
DC Transmission Technology Key State Laboratories,China Southern Power Grid Research Institute Co.,Ltd.