Research Progress on Influence of Water Content of Oil-paper Insulation on Partial Discharge of Converter Transformer
|更新时间:2025-12-08
|
Research Progress on Influence of Water Content of Oil-paper Insulation on Partial Discharge of Converter Transformer
Vol. 47, Issue 8, Pages: 2932-2945(2021)
作者机构:
天津大学电气自动化与信息工程学院
作者简介:
基金信息:
DOI:
CLC:
Published Online:31 August 2021,
Published:2021
稿件说明:
移动端阅览
DU Boxue, JIANG Jinpeng. Research Progress on Influence of Water Content of Oil-paper Insulation on Partial Discharge of Converter Transformer[J]. 2021, 47(8): 2932-2945.
DOI:
DU Boxue, JIANG Jinpeng. Research Progress on Influence of Water Content of Oil-paper Insulation on Partial Discharge of Converter Transformer[J]. 2021, 47(8): 2932-2945.DOI:
Research Progress on Influence of Water Content of Oil-paper Insulation on Partial Discharge of Converter Transformer
Converter transformer is the core equipment in HVDC transmission system
which plays a key role in connecting AC and DC system. Oil-paper insulation is the main insulation of converter transformer
whose insulation performance is of great significance to the transmission system. Moisture will inevitably exist in the oil-paper insulation system due to insulation aging and external moisture intrusion. Meanwhile
moisture not only significantly reduces the dielectric strength of the insulation
but also is adsorbed onto the surface of the insulation paper
increases the number of interface defects and distorts the local electric field
and causes partial discharge or even insulation failure
which pose a great threat to the reliability of the oil-paper insulation system and the stable operation of the converter transformer. We review its research status in the world
analyze the source
existing state and distribution characteristics of moisture in converter transformers
explore the internal mechanism and dynamic law of moisture balance and migration in oil-paper insulation
and summarize the law and mechanism of moisture effect on the characteristics of charge and partial discharge of oil-paper insulation under operating conditions. The dynamic behavior of moisture at the interface of oil-paper insulation is emphasized especially. It is pointed out that the influence of transient process of water migration on the charge and partial discharge of oil-paper insulation under operating conditions can not be neglected.
Partial Discharge Characteristics of Needle-plate Electrodes in Aging Oil-paper Insulation Under Combined AC-DC Voltage
Review on Partial Discharge and Charge Distribution Characteristics of Oil-paper Insulation in Converter Transformer
Simulation and Verification of Interface Charge Accumulation Influence on Electric Field Distribution of "Liquid-Solid" Oil-paper Insulation Under DC Voltage
Discharge Characteristics of the Typical Defects in Oil-paper Insulation Under AC-DC Compound Voltage
Effect of Re-applied and Pre-pressing DC Voltage on the Characteristics of Partial Discharge Within Oil-paper Insulation
Related Author
SI Wen
LI Tianjiao
LI Simeng
LI Haibo
QIN Bingyang
LI Qingquan
LI Qingquan
WANG Liangkai
Related Institution
Shandong Provincial Key Laboratory of UHV Transmission Technology and Equipment, School of Electrical Engineering,Shandong University
College of Mechanical and Electrical Engineering, Northeast Forestry University
Tai’an Power Supply Company, State Grid Shandong Electric Power Company
Shandong Provincial Key Laboratory of UHV Transmission Technology and Equipment, Shandong University
State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University