电网不对称时并网逆变器不同约束条件下控制问题分析

Analysis of Control Strategy for Grid-connected Inverter Under Different Constraints Based on Asymmetric Grid

  • 摘要: 当三相电网不对称时,基于传统双闭环控制策略的并网逆变器将在直流侧和交流侧分别产生偶数次和奇数次谐波,从而影响并网逆变器系统的性能。针对这一问题,文中提出在正负序旋转坐标系下实现并网的控制策略,该控制策略基于电网不对称下的并网逆变器数学模型以及功率波动形式,由不同的控制目标得到不同约束条件(内环参考指令电流),并设计了相应的控制方法。为了有效并快速地分离出正负序量,提出了一种瞬时正负序分离方法,采用遗忘积分算法进行滤波。最后对比了各个控制目标下的实验结果,验证了所提出的正负序分离算法可快速地提取出电网电压的相角信息,且算法实现较简单。

     

    Abstract: When a three-phase grid is unbalanced,the grid-connected inverter based on the traditional double-loop control strategy will generate even-numbered and odd-numbered harmonics on the DC side and AC side,respectively,which will seriously affect the performance of the grid-connected inverter system.For this reason,the control strategy of grid connection is proposed to realize under the positive-negative sequence rotational coordinate system.With the control strategy,different constraint conditions are obtained from different control objectives(inner current reference)and the corresponding control method is designed.To effectively and rapidly separate positive and negative sequences,an instantaneous positive-negative sequence separating method is presented.The forgetting integration algorithm is adopted for filtering.Experimental results under various control objectives are compared to show the effectiveness and simplicity of the algorithm.

     

/

返回文章