张浩, 胡振兴. 大型H级调峰燃机电站主接线优化设计[J]. 电力勘测设计, 2024, (1): 31-34. DOI: 10.13500/j.dlkcsj.issn1671-9913.2024.01.007
引用本文: 张浩, 胡振兴. 大型H级调峰燃机电站主接线优化设计[J]. 电力勘测设计, 2024, (1): 31-34. DOI: 10.13500/j.dlkcsj.issn1671-9913.2024.01.007
ZHANG Hao, HU Zhen-xing. Optimization Design of Main Single Line Diagram of Large-Scale H-Class Peak Shaving Gas Turbine Power Station[J]. Electric Power Survey & Design, 2024, (1): 31-34. DOI: 10.13500/j.dlkcsj.issn1671-9913.2024.01.007
Citation: ZHANG Hao, HU Zhen-xing. Optimization Design of Main Single Line Diagram of Large-Scale H-Class Peak Shaving Gas Turbine Power Station[J]. Electric Power Survey & Design, 2024, (1): 31-34. DOI: 10.13500/j.dlkcsj.issn1671-9913.2024.01.007

大型H级调峰燃机电站主接线优化设计

Optimization Design of Main Single Line Diagram of Large-Scale H-Class Peak Shaving Gas Turbine Power Station

  • 摘要: 国内大型H级调峰燃机电站,一般都设置发电机出口断路器(generator circuit-breaker,GCB)。基于相关标准及实际运行需求,对燃机电站GCB设置方式进行分析研究,提出一种大型H级调峰燃机主接线优化设计方案,并通过技术经济分析论证此方案的技术可行性和经济性。

     

    Abstract: At present, domestic large-scale H-class peak shaving gas turbine power stations are generally equipped with generator circuit breaker(GCB). Based on relevant standards and actual operation requirements, this paper analyzes and studies the GCB setting mode of gas turbine power station, puts forward an optimized design scheme for the main single line diagram of large-scale H-class peak shaving gas turbine, and demonstrates the technical feasibility and economy of this scheme through technical and economic analysis.

     

/

返回文章