电站锅炉空气预热器跳闸分析与处理
Analysis and Treatment of Air Preheater Trip in Power Plant Boiler
-
摘要: 某厂空气预热器因蓄热元件损坏严重,存在很大安全隐患。运行中出现了空气预热器卡涩跳闸,排烟温度大幅升高,严重威胁锅炉安全运行。分析了空气预热器卡涩跳闸原因,并提出防范措施。Abstract: The air preheater in a factory is seriously damaged due to the thermal storage element,which has a great potential safety hazard. During the operation,the air preheater jammed and tripped,and the exhaust gas temperature increased significantly,which seriously threatened the safe operation of the boiler. It analyzes the cause of air preheater jam trip,and puts forward preventive measures to guide the operation adjustment.