  • 摘要: 青海某热电厂原水预处理系统频繁爆发红虫污染,本文分析了红虫污染出现原因,通过实验选取了二氧化氯作为灭活药剂,确定了二氧化氯最佳投加量及接触时间;提出了再生水中红虫处理可采用先过滤富集,再序批处理的灭活方案,并提供了再生水系统的具体改造措施。

     

    Abstract: In a thermal power plant of Qinghai Province, red worm pollution frequently occurs in the pretreatment system of raw water. This paper analyzed the causes of red worm pollution, selects chlorine dioxide as an inactivating agent through experiments, and determines the best dosage and the best contact time. It puts forward the transformation idea of filtering and enriching the red worm in the regeneration water firstly, then batch inactivating it, and provides a specific transformation scheme.

     

/