  • 摘要: 基于±1100kV昌吉-古泉特高压分层接入直流输电工程,通过PSCAD/EMTDC电磁暂态仿真软件搭建考虑层间耦合的特高压直流分层接入仿真模型。对比分层接入与传统接入方式下交流系统强度的差异,仿真计算不同耦合强度下分层接入交流系统有效层间短路比的变化特性。通过研究层间联系阻抗对系统稳态运行特性及故障下系统换相失败特性的影响规律,分析稳态及暂态下逆变侧不同交流系统层间的交互作用,为分层接入特高压直流输电系统输电稳定性提供理论支持。

     

    Abstract: Based on ±1100kV Changji-Guquan UHVDC hierarchical con-nection mode transmission project, the simulation model of UHVDC considering interlayer coupling is set up by PSCAD/EMTDC electromagnetic transient simulation software. The difference of the AC system strength between the hierar-chical connection mode and the traditional connection mode is compared, and the variation characteristics of the effective inter-layer short circuit ratio of the hierarchical connected AC system under different coupling strengths are simulated. By studying the influence law of the interlayer impedance on the steady-state system operation characteristics and the system commutation failure characteristics under the fault, the interaction between the different AC systems of the inverter side under steady state and transient state is analyzed. The results of this paper can provide theoretical support for the operation stability of UHVDC hierar-chical connection mode transmission system.

     

/