600MW超临界锅炉干-湿态转换操作过程及问题分析
Operation process and problem analysis of dry-wet state conversion for 600MW supercritical boiler
-
摘要: 摘 要:本文介绍了华能上安电厂600MW超临界带有内置式分离器锅炉干-湿态转换操作的要点及注意事项,并针对运行中出现的问题进行总结,根据经验提出优化调整方式,对同类型机组的启动调试和运行具有一定的参考作用。Abstract: ABSTRACT: This paper introduces the key points and precautions of dry-wet state conversion operation of 600MW supercritical boiler with built-in separator in Huaneng Shangan Power Plant, and summarizes the problems in operation. According to the experience, the optimization adjustment method is proposed, which has a certain reference role for the start-up, debugging and operation of the same type of units.