  • 摘要: 对主机遮断控制系统发生的故障进行分析,机组正常运行时发电控制及机组发生异常时,DEH供电系统的稳定可靠非常重要,当ETS电源发生故障AST电磁阀失电时,为保证汽轮机的安全稳定运行,有针对性的提出解决方式和治理措施,从技术处理和专业管理等方面提升控制系统维护工作的规范性,总结分析热控电源系统故障的主要因素,避免类似问题发生时能快速有效的处理。

     

    Abstract: This paper analyzes the faults of the main unit outage control system, the stability and reliability of the DEH power supply system is very important when the unit is in normal operation and the generating control is abnormal, in order to ensure the safe and stable operation of the steam turbine when the AST solenoid valve loses power when the ETS power supply fails, the solving methods and treatment measures are put forward pertinently, to improve the standardization of control system maintenance from the aspects of technical treatment and professional management, summarize and analyze the main factors of thermal control power system failure, avoid the occurrence of similar problems can be dealt with quickly and effectively.

     

/